Thru-Beam Sensor OBE2000-R2-SE2-0,2M-V31 Pepperl+Fuchs 262342
Thru-Beam Sensor OBE2000-R2-SE2-0,2M-V31 Pepperl+Fuchs 262342

We are not the manufacturer, authorised distributor or authorised representative of the Pepperl+Fuchs brand in Australia. The private labels and part numbers shown on this website are the property of their respective owners.

Pepperl+Fuchs OBE2000-R2-SE2-0,2M-V31 262342

Manufacturer

Pepperl+Fuchs

Country

Germany

Name

OBE2000-R2-SE2-0,2M-V31

Part number

262342

Type

Thru-Beam Sensor

Description

Thru-beam sensor OBE2000-R2-SE2-0,2M-V31

Stock availability:

On request

Price: On request

Order

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications OBE2000-R2-SE2-0,2M-V31 262342

The nano sensor has been developed for a broad range of applications. It offers excellent durability and is exceptionally easy to install. The housing is compact and, with its 45° cable outlet, can be installed in the smallest spaces. New functional principles and functionality open up a range of new options. The abrasion-resistant lens allows long operating times close to the moving object.

Features OBE2000-R2-SE2-0,2M-V31 262342

Product Description
Thru-beam sensor for standard applications, miniature design, 2000 mm detection range, red light, dark on, PNP output, fixed cable
System components
EmitterOBE2000-R2-0,2M-V31
ReceiverOBE2000-R2-E2-0,2M-V31
General specifications
Effective detection rangeLong range mode: 0 ... 2 m High precision mode: 0 ... 200 mm
Threshold detection rangeLong range mode: 2.5 m High precision mode: 300 mm
Light sourceLED
Light typemodulated visible red light , 630 nm
Angle deviationapprox. 2 °
Diameter of the light spotLong range mode: 150 mm at a distance of 2000 mm High precision mode: 0.5 mm at a distance of 50 mm
Angle of divergenceapprox. 2 °
Optical facefrontal
Ambient light limitEN 60947-5-2 : 30000 Lux
Functional safety related parameters
MTTFd806 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Indicators/operating means
Operation indicatorLED green, statically lit Power on , short-circuit : LED green flashing (approx. 4 Hz)
Function indicatorReceiver: LED yellow, lights up when light beam is free, flashes when falling short of the stability control , OFF when light beam is interrupted
Electrical specifications
Operating voltage10 ... 30 V DC , class 2
No-load supply currentEmitter: &le, 11 mA Receiver: &le, 8 mA
Input
Control inputEmitter selection BK: not connected, Long Range mode BK: 0 V, High Precicion Mode
Switching thresholdTeach-In input
Output
Switching typeNO contact
Signal output1 PNP output, short-circuit protected, reverse polarity protected, open collector
Switching voltagemax. 30 V DC
Switching currentmax. 50 mA
Voltage drop&le, 1.5 V DC
Switching frequencyapprox. 800 Hz
Response time600 µ,s
Conformity
Product standardEN 60947-5-2
Approvals and certificates
UL approvalcULus Recognized, Class 2 Power Source
CCC approvalCCC approval / marking not required for products rated &le,36 V
Ambient conditions
Ambient temperature-25 ... 60 °C (-13 ... 140 °F)
Storage temperature-30 ... 70 °C (-22 ... 158 °F)
Mechanical specifications
Housing width7.5 mm
Housing height24 mm
Housing depth11.2 mm
Degree of protectionIP67
Connection200 mm fixed cable with 4-pin, M8x1 connector
Material
HousingPC/ABS and TPU
Optical faceglass
CablePUR
InstallationFixing screws , 2 x M2 allen head screws included with delivery
Massapprox. 20 g Per sensor
Cable length200 mm