Level Limit Switch

Description

  • Switch element: microswitch, mercury-free
  • Limit value detection for fluids
  • Sleeve design: small diameter, mounting through G1 tap hole possible

Stock availability:

On request

105.29 €

Need cheaper?

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications LFL2-CK-U-PUR5-EMS 262201

The microswitch (change-over contact) is integrated in a PP float and is activated in the event of deviations from the horizontal position. The switching ball in the float, which moves along an axis, activates the microswitch.

Features LFL2-CK-U-PUR5-EMS 262201

Electrical specifications
Contact loading250 V AC/3 A, 150 V DC/0.25 A resistive load, 60 V DC/1 A resistive load
Rated insulation voltage300 V
Pulse withstand voltage4 kV
Electrical life&ge, 5 x 104 switching cycles
Directive conformity
Low voltage
Directive 2014/35/EUEN 60947-5-1:2004 + Cor.:2005 + A1:2009
Conformity
Degree of protectionIEC 60529:2001
Application
Descriptionmicroswitch with switching ball, change-over contact
Function and system design
Equipment architectureThis device may be used with any sequential circuit, as long as the circuit can support the electrical circuit values of the switching elements.
Operating conditions
Installation conditions
Installation instructionsrange of application and minimum length between mounting and float: &ge, 100 mm (4 inch), preferred for fuels, heating oils, oily fluids mounting: - The float switch is mounted either from sidewards through a cable gland &ge, G1A into the vessel or - by means of a counter weight or rods (e. g. float switch combination) from the top. The pivot of the cable should always be horizontal.
Process conditions
Process pressure (static pressure)&le, 3 bar (43.5 psi) at 20 °C (68 °F)
Density&ge, 0.8 g/cm3
Ambient conditions
Ambient temperature5 ... 70 °C (41 ... 158 °F)
Storage temperature-25 ... 70 °C (-13 ... 158 °F)
Altitude&le, 2000 m above MSL
Mechanical specifications
Degree of protectionIP68
Cable
Length5 m
Mechanical construction
Materialfloat: PP (Polypropylene) cable: PUR, highly flexible (3 x 0.50 mm2)
Switching pointswitch angle, measured against the horizontal: - upper switch point +25° ±10° - lower switch point -14° ±10°
General information
Supplementary informationStatement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.