Current Driver HIC2031HC Pepperl+Fuchs 226027
Current Driver HIC2031HC Pepperl+Fuchs 226027

We are not the manufacturer, authorised distributor or authorised representative of the Pepperl+Fuchs brand in Australia. The private labels and part numbers shown on this website are the property of their respective owners.

Pepperl+Fuchs HIC2031HC 226027

Manufacturer

Pepperl+Fuchs

Country

Germany

Name

HIC2031HC

Part number

226027

Type

Current Driver

Description

  • 1-channel isolated barrier
  • 24 V DC supply (bus powered)
  • Current output up to 625 &Omega, load
  • HART I/P and valve positioner
  • Low power dissipation
  • Suitable for long field cables (> 1000 m)
  • Up to SIL 2 acc. to IEC 61508

Stock availability:

On request

365.5 €

Need cheaper?

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications HIC2031HC 226027

This isolated barrier is used for intrinsic safety applications. It repeats the input signal from a control system to drive HART I/P converters, valve actuators, and displays located in a hazardous area. Bi-directional communication is supported for HART devices. An open field circuit presents a high impedance to the control side to allow alarm conditions to be monitored by control systems. This device mounts on a HiC Termination Board.

Features HIC2031HC 226027

General specifications
Signal typeAnalog output
Functional safety related parameters
Safety Integrity Level (SIL)SIL 2
Supply
ConnectionSL1: 1a(-), 1b(-), 2a(+), 2b(+)
Rated voltage19 ... 30 V DC bus powered via Termination Board
Ripple&le, 10 %
Rated current&le, 35 mA
Power dissipation&le, 600 mW
Power consumption&le, 700 mW
Input
Connection sidecontrol side
ConnectionSL1: 8a(+), 7a(-)
Input signal4 ... 20 mA , limited to approx. 27 mA
Input voltagedepending on switch configuration open loop voltage of the control system < 19 V open loop voltage of the control system < 26 V
Voltage dropdepending on switch configuration open loop voltage of the control system < 19 V: approx. 5 V at 20 mA open loop voltage of the control system < 26 V: approx. 12 V at 20 mA
Input resistance> 100 k&Omega,, with field wiring open
Output
Connection sidefield side
ConnectionSL2: 5a(+), 5b(-)
Current4 ... 20 mA
Load0 ... 625 &Omega,
Voltage&ge, 12.5 V at 20 mA
Ripple20 mV rms
Transfer characteristics
Deviationat 20 °C (68 °F), 4 ... 20 mA &le, ± 0.1 % incl. non-linearity and hysteresis
Frequency rangefield side into the control side: bandwidth with 0.5 Vpp signal 0 ... 3 kHz (-3 dB) control side into the field side: bandwidth with 1 mApp signal 0 ... 3 kHz (-3 dB)
Rise time10 to 90 % &le, 100 ms
Indicators/settings
Display elementsLED
Control elementsDIP-switch
Configurationvia DIP switches
Labelingspace for labeling at the front
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013 (industrial locations)
Conformity
Electromagnetic compatibilityNE 21:2012 For further information see system description.
Degree of protectionIEC 60529
Ambient conditions
Ambient temperature-20 ... 60 °C (-4 ... 140 °F)
Mechanical specifications
Degree of protectionIP20
Massapprox. 100 g
Dimensions12.5 x 128 x 106 mm (0.5 x 5.1 x 4.2 inch)
Mountingon Termination Board
Data for application in connection with hazardous areas
EU-Type Examination CertificateCESI 11 ATEX 012
Marking II (1)GD [Ex ia] IIC, [Ex iaD] [circuit(s) in zone 0/1/2/20/21/22] I (M1) [Ex ia] I
CertificatePF 11 CERT 1845 X
Marking II 3G Ex nA IIC T4 Gc
Directive conformity
Directive 2014/34/EUEN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010
International approvals
UL approval
Control drawing116-0393 (cULus)
IECEx approvalIECEx CES 11.0010