We are not the manufacturer, authorised distributor or authorised representative of the Pepperl+Fuchs brand in Australia. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Pepperl+Fuchs
Country
Germany
Name
NJ8-18GM-N-10M
Part number
196916
Type
Inductive sensor
Description
Inductive sensor NJ8-18GM-N-10M
Stock availability:
On request
If you require NJ8-18GM-N-10M 196916 from manufacturer Pepperl+Fuchs, please contact FAMAGA.
For more than 9 years our employees supply repair parts for the upgrade and maintenance of various types of manufacturing equipment from all over the world. Over 600 orders from clients from countries of near and far abroad are in service daily. Developed partner network provides an opportunity to execute without delay order for Pepperl+Fuchs NJ8-18GM-N-10M, while the client does not have to go over budget.
Geography of deliveries involves Europe, Asia, Africa and America. Australia, India, Indonesia, United States, Tunisia, Ukraine, Kenya, Nigeria, Djibouti, Eswatini, Bahrain, Yemen, Angola, Bulgaria, Japan, Malta, Sudan, Fiji, Côte d\'Ivoire, Myanmar, The Bahamas, Barbados, Montenegro, Belize, Nicaragua, Liechtenstein, Colombia, South Sudan, Switzerland, Singapore, Eritrea, Germany, Guinea-Bissau, Dominica, Sri Lanka, Suriname, Madagascar, Turkey, Burundi, Equatorial Guinea, Poland, Comoros, Guyana, Ecuador, China, Luxembourg, Botswana There is no restrictions on the size and mass of the cargo. We developed different delivery options so that a client can choose suitable balance between cost and delivery time.
Company`s fundamental rule of operation is transparency, which covers every segment of activity. Customers get top-class spare parts and equipment, to which factory warranty applies. All spare parts and equipment are original, risk of presence of counterfeits are excluded. For permanent customers there are exclusive offers and they are valid great deals.
Become an orderer from FAMAGA, get industrial machinery fast and at beneficial price. Fill in information in the order form on the website. Our employee will contact you to specify details. Inquiries are also accepted by phone.
General specifications | ||
---|---|---|
Switching function | Normally closed (NC) | |
Output type | NAMUR | |
Rated operating distance | 8 mm | |
Installation | non-flush | |
Assured operating distance | 0 ... 6.48 mm | |
Reduction factor rAl | 0.4 | |
Reduction factor rCu | 0.3 | |
Reduction factor r304 | 0.85 | |
Output type | 2-wire | |
Nominal ratings | ||
Nominal voltage | 8 V | |
Operating voltage | 5 ... 25 V | |
Switching frequency | 0 ... 200 Hz | |
Hysteresis | 3 % | |
Current consumption | ||
Measuring plate not detected | &ge, 3 mA at nominal voltage | |
Measuring plate detected | &le, 1 mA at nominal voltage | |
Compliance with standards and directives | ||
Standard conformity | ||
NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
Standards | EN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 | |
Approvals and certificates | ||
EAC conformity | TR CU 012/2011 | |
FM approval | ||
Control drawing | 116-0165 | |
UL approval | ||
Ordinary Location | E87056 | |
Hazardous Location | E501628 | |
Control drawing | 116-0452 | |
CSA approval | cCSAus Listed, General Purpose | |
CCC approval | CCC approval / marking not required for products rated &le,36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) | |
Mechanical specifications | ||
Connection type | cable PVC , 10 m | |
Core cross-section | 0.75 mm2 | |
Housing material | Stainless steel 1.4305 / AISI 303 | |
Sensing face | PBT | |
Degree of protection | IP67 | |
Cable | ||
Cable diameter | 6 mm ± 0.2 mm | |
Bending radius | > 10 x cable diameter | |
Equipment protection level Ga | ||
CE marking | [*PD-Z02585A*] | |
ATEX marking | II 1G Ex ia IIC T6&hellip,T1 Ga The Ex-related marking can also be printed on the enclosed label. | |
Standards | EN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection Intrinsic safety Use is restricted to the following stated conditions | |
Appropriate type | NJ 8-18GM-N... | |
Effective internal capacitance | max. 70 nF , a cable length of 10 m is considered. | |
Effective internal inductance | max. 50 µ,H , a cable length of 10 m is considered. | |
Ambient temperature | Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EC-type examination certificate. Note: Use the temperature table for category 1 !!! The 20 % reduction in accordance with EN 1127-1 has already been applied to the temperature table for category 1. | |
Equipment protection level Gb | ||
CE marking | [*PD-Z02585A*] | |
ATEX marking | II 1G Ex ia IIC T6&hellip,T1 Ga The Ex-significant identification is on the enclosed adhesive label | |
Standards | EN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection Intrinsic safety Use is restricted to the following stated conditions | |
Appropriate type | NJ 8-18GM-N... | |
Effective internal capacitance | max. 70 nF , a cable length of 10 m is considered. | |
Effective internal inductance | max. 50 µ,H , a cable length of 10 m is considered. | |
Maximum permissible ambient temperature | Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EC-type examination certificate. | |
Equipment protection level Da | ||
CE marking | [*PD-Z02585A*] | |
ATEX marking | II 1D Ex ia IIIC T135°C Da The Ex-related marking can also be printed on the enclosed label. | |
Standards | EN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection Intrinsic safety Use is restricted to the following stated conditions | |
Appropriate type | NJ 8-18GM-N... | |
Effective internal capacitance | max. 70 nF , a cable length of 10 m is considered. | |
Effective internal inductance | max. 50 µ,H , a cable length of 10 m is considered. | |
Maximum permissible ambient temperature | Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the surface temperature, and the effective internal reactance values can be found on the EC-type-examination certificate. The maximum permissible ambient temperature of the data sheet must be noted, in addition, the lower of the two values must be maintained. | |
General information | ||
Use in the hazardous area | see instruction manuals | |
Category | 1G, 2G, 1D |