We are not the manufacturer, authorised distributor or authorised representative of the Pepperl+Fuchs brand in Australia. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Pepperl+Fuchs
Country
Germany
Name
VAA-2E2A-G12-SAJ/EA2L
Part number
193671
Type
Safety module
Description
Stock availability:
On request
Product Description |
---|
G12 safety module 2 safety inputs and 2 standard electronic outputs |
General specifications | ||
---|---|---|
Slave type | Safety-Slave | |
AS-Interface specification | V2.1 | |
Required master specification | &ge, V2.1 | |
UL File Number | E223772 | |
Functional safety related parameters | ||
Safety Integrity Level (SIL) | SIL 3 | |
Performance level (PL) | PL e | |
Category | Cat. 4 | |
MTTFd | no significant contribution to MTTFd of the overall system | |
PFHd | no significant contribution to PFH of the overall system | |
PFD | no significant contribution to PFD of the overall system | |
Indicators/operating means | ||
LED FAULT | error display, LED red red: communication error or address is 0 red flashing: Output supply overload | |
LED PWR | AS-Interface voltage, green LED green: voltage OK flashing green: address 0 | |
LED AUX | ext. auxiliary voltage UAUX, dual LED green/red green: voltage OK red: reverse voltage | |
LED IN | switching state (input), 2 LED yellow | |
LED OUT | Switching status (output), 2 yellow/red LEDs Yellow: output active Red: output overload | |
Electrical specifications | ||
Auxiliary voltage (output) | 24 V DC ± 15 % PELV | |
Rated operating voltage | 26.5 ... 31.6 V from AS-Interface | |
Rated operating current | &le, 50 mA | |
Protection class | III | |
Surge protection | UAUX, Uin: Over voltage category III, safe isolated power supplies (PELV) derived from mains up to 300 V AC line-to-neutral | |
Rated insulation voltage | 40 V | |
Pulse withstand voltage | 0.5 kV | |
Input | ||
Number/Type | 2 safety-related inputs for mechanical contacts, crossed-circuit monitored: 2 single-channel contacts: up to category 2/PL c to ISO 13849-1 or 1 2-channel contact: up to category 4/PL e to ISO 13849-1 Cable length must not exceed 300 m per input. | |
Supply | from AS-Interface | |
Voltage | 20 ... 30 V DC pulsed | |
Current loading capacity | input current limited &le, 15 mA, overload and short-circuit resistant | |
Output | ||
Number/Type | 2 conventional electronic outputs, PNP | |
Supply | from external auxiliary voltage UAUX | |
Voltage | &ge, (UAUX - 0.5 V) | |
Current | 1.5 A per output , short-circuit protected | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 62026-2:2013 EN 61000-6-2:2005 EN 61000-6-4:2007 | |
Machinery Directive | ||
Directive 2006/42/EC | EN ISO 13849-1:2008 + AC:2009 EN ISO 13849-2:2012 EN 62061:2005 | |
Standard conformity | ||
Insulation coordination | EN 60947-1:2007 | |
Degree of protection | EN 60529:2000 | |
Fieldbus standard | EN 62026-2:2013 | |
Electrical safety | IEC 60947-1, NFPA 79, IEC 60204-1:2007 | |
Emitted interference | EN 61000-6-4:2007/A1:2011 | |
AS-Interface | EN 62026-2:2013 | |
Noise immunity | IEC 62026-2:2008 EN 62061:2005 EN 61000-6-2:2005 | |
Functional safety | ISO 13849-1 (up to category 4/PL e), IEC 61508/IEC 62061 (up to SIL3) | |
Standards | NFPA 79:2007 ER 1 | |
Programming instructions | ||
Profile | S-7.B | |
IO code | 7 | |
ID code | B | |
ID1 code | F | |
ID2 code | 0 | |
Data bits (function via AS-Interface) | input output | |
D0 | dyn. safety code 1 OUT 1 | |
D1 | dyn. safety code 1 OUT 2 | |
D2 | dyn. safety code 2 - | |
D3 | dyn. safety code 2 - | |
Parameter bits (programmable via AS-i) | function | |
P0 | communication monitoring P0 = 1 (default settings), monitoring = ON, i.e. if communication fails, the outputs are de-energised P0 = 0, monitoring = OFF, if communication fails, the outputs maintain their condition | |
P1 | Logic operation: P0 = 1 (default settings): The outputs are controlled via AS-Interface. P0 = 0: The outputs are controlled via AS-Interface or the inputs. The corresponding output is activated on opening the contacts of an input. | |
P2 | not used | |
P3 | not used | |
Ambient conditions | ||
Ambient temperature | -25 ... 60 °C (-13 ... 140 °F) | |
Storage temperature | -25 ... 85 °C (-13 ... 185 °F) | |
Relative humidity | 85 % , noncondensing | |
Climatic conditions | For indoor use only | |
Altitude | &le, 2000 m above MSL | |
Shock and impact resistance | 30 g, 11 ms in 6 spatial directions 3 shocks 10 g, 16 ms in 6 spatial directions 1000 shocks | |
Vibration resistance | 0.75 mm 10 ... 57 Hz , 5 g 57 ... 150 Hz, 20 cycles | |
Pollution degree | 3 | |
Mechanical specifications | ||
Degree of protection | IP67 | |
Connection | Cable piercing method flat cable yellow/flat cable black inputs/outputs: M12 round connector | |
Material | ||
Housing | PBT | |
Mass | 200 g | |
Tightening torque, cable gland | 0.4 Nm | |
Mounting | Mounting plate |