Inductive sensor NCB8-18GM40-N0-V1 Pepperl+Fuchs 181089
Inductive sensor NCB8-18GM40-N0-V1 Pepperl+Fuchs 181089

We are not the manufacturer, authorised distributor or authorised representative of the Pepperl+Fuchs brand in Australia. The private labels and part numbers shown on this website are the property of their respective owners.

Pepperl+Fuchs NCB8-18GM40-N0-V1 181089

Manufacturer

Pepperl+Fuchs

Country

Germany

Name

NCB8-18GM40-N0-V1

Part number

181089

Type

Inductive sensor

Description

Inductive sensor NCB8-18GM40-N0-V1

Stock availability:

On request

Price: On request

Order

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications NCB8-18GM40-N0-V1 181089

If you require NCB8-18GM40-N0-V1 181089 from manufacturer Pepperl+Fuchs, please contact FAMAGA.

For more than 8 years our managers supply spare parts for the upgrade and maintenance of various types of manufacturing equipment from all parts of the planet. Over 750 orders from clients from different countries are in progress daily. Developed partner network provides an opportunity to execute without delay order for Pepperl+Fuchs NCB8-18GM40-N0-V1, while the buyer does not have to go over budget.

Geography of deliveries involves Europe, Asia, Africa and America. There is no restrictions on the size and mass of the cargo. We submit for review different delivery options so that a customer can choose suitable balance between cost and delivery time.

Company`s main principle of operation is transparency, which involves every direction of activity. Clients get top-class spare parts and equipment, to which factory warranty applies. All repair parts and equipment are original, risk of presence of counterfeits are excluded. For permanent partners there are bonus programs and they are valid special pricing.

Become an orderer from FAMAGA, get equipment fast and at beneficial price. Fill in the order form on the website. Our employee will contact you to discuss details. Requests are also accepted by phone.

Features NCB8-18GM40-N0-V1 181089

General specifications
Switching functionNormally closed (NC)
Output typeNAMUR
Rated operating distance8 mm
Installationflush
Assured operating distance0 ... 6.48 mm
Actual operating distance7.2 ... 8.8 mm typ. 8 mm
Reduction factor rAl 0.39
Reduction factor rCu 0.36
Reduction factor r304 0.71
Output type2-wire
Nominal ratings
Nominal voltage8.2 V (Ri approx. 1 k&Omega,)
Switching frequency0 ... 1500 Hz
Hysteresis1 ... 15 typ. 5 %
Reverse polarity protectionreverse polarity protected
Short-circuit protectionyes
Suitable for 2:1 technologyyes , Reverse polarity protection diode not required
Current consumption
Measuring plate not detectedmin. 2.2 mA
Measuring plate detected&le, 1 mA
Switching state indicatorMultihole-LED, yellow
Functional safety related parameters
MTTFd2660 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Compliance with standards and directives
Standard conformity
NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999
Electromagnetic compatibilityNE 21:2007
StandardsEN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012
Approvals and certificates
EAC conformityTR CU 012/2011
FM approval
Control drawing116-0165
UL approval
Ordinary LocationE87056
Hazardous LocationE501628
Control drawing116-0452
CSA approvalcCSAus Listed, General Purpose
CCC approvalCCC approval / marking not required for products rated &le,36 V
Ambient conditions
Ambient temperature-25 ... 100 °C (-13 ... 212 °F)
Storage temperature-40 ... 100 °C (-40 ... 212 °F)
Mechanical specifications
Connection typeConnector plug M12 x 1 , 4-pin
Housing materialStainless steel 1.4305 / AISI 303
Sensing facePBT
Degree of protectionIP66 / IP67
Equipment protection level Ga
CE marking[*PD-Z02585A*]
ATEX marking II 1G Ex ia IIC T6&hellip,T1 Ga The Ex-related marking can also be printed on the enclosed label.
StandardsEN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection Intrinsic safety Use is restricted to the following stated conditions
Appropriate typeNCB8-18GM...-N0...
Effective internal capacitancemax. 120 nF , a cable length of 10 m is considered.
Effective internal inductancemax. 50 µ,H , a cable length of 10 m is considered.
Ambient temperatureDetails of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EC-type examination certificate. Note: Use the temperature table for category 1 !!! The 20 % reduction in accordance with EN 1127-1 has already been applied to the temperature table for category 1.
Equipment protection level Gb
CE marking[*PD-Z02585A*]
ATEX marking II 1G Ex ia IIC T6&hellip,T1 Ga The Ex-significant identification is on the enclosed adhesive label
StandardsEN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection Intrinsic safety Use is restricted to the following stated conditions
Appropriate typeNCB8-18GM...-N0...
Effective internal capacitancemax. 120 nF , a cable length of 10 m is considered.
Effective internal inductancemax. 50 µ,H , a cable length of 10 m is considered.
Maximum permissible ambient temperatureDetails of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EC-type examination certificate.
Equipment protection level Gc (ic)
CertificatePF 13 CERT 2895 X
CE marking[*PD-Z02586A*]
ATEX marking II 3G Ex ic IIC T6&hellip,T1 Gc The Ex-significant identification is on the enclosed adhesive label
StandardsEN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection category ic Use is restricted to the following stated conditions
Effective internal capacitancemax. 120 nF , a cable length of 10 m is considered.
Effective internal inductancemax. 50 µ,H , A cable length of 10 m is considered.
Special conditions
for Pi=34 mW, Ii=25 mA, T674 °C (165.2 °F)
for Pi=34 mW, Ii=25 mA, T589 °C (192.2 °F)
for Pi=34 mW, Ii=25 mA, T4-T1100 °C (212 °F)
for Pi=64 mW, Ii=25 mA, T669 °C (156.2 °F)
for Pi=64 mW, Ii=25 mA, T584 °C (183.2 °F)
for Pi=64 mW, Ii=25 mA, T4-T1100 °C (212 °F)
for Pi=169 mW, Ii=52 mA, T651 °C (123.8 °F)
for Pi=169 mW, Ii=52 mA, T566 °C (150.8 °F)
for Pi=169 mW, Ii=52 mA, T4-T174 °C (165.2 °F)
for Pi=242 mW, Ii=76 mA, T639 °C (102.2 °F)
for Pi=242 mW, Ii=76 mA, T552 °C (125.6 °F)
for Pi=242 mW, Ii=76 mA, T4-T152 °C (125.6 °F)
Equipment protection level Gc (nL)
Standard conformityEN 60079-15:2003 Ignition protection category n Use is restricted to the following stated conditions
Effective internal capacitance Cimax. 120 nF , a cable length of 10 m is considered.
Effective internal inductance Limax. 50 µ,H , A cable length of 10 m is considered.
GeneralThe apparatus has to be operated according to the appropriate data in the data sheet and in this instruction manual. The data stated in the data sheet are restricted by this operating instruction! The special conditions must be observed! The ATEX Directive applies only to the use of apparatus under atmospheric conditions. If you use the device outside atmospheric conditions, consider that the permissible safety parameters should be reduced.
Special conditions
for Pi=34 mW, Ii=25 mA, T674 °C (165.2 °F)
for Pi=34 mW, Ii=25 mA, T589 °C (192.2 °F)
for Pi=34 mW, Ii=25 mA, T4-T1100 °C (212 °F)
for Pi=64 mW, Ii=25 mA, T669 °C (156.2 °F)
for Pi=64 mW, Ii=25 mA, T584 °C (183.2 °F)
for Pi=64 mW, Ii=25 mA, T4-T1100 °C (212 °F)
for Pi=169 mW, Ii=52 mA, T651 °C (123.8 °F)
for Pi=169 mW, Ii=52 mA, T566 °C (150.8 °F)
for Pi=169 mW, Ii=52 mA, T4-T174 °C (165.2 °F)
for Pi=242 mW, Ii=76 mA, T639 °C (102.2 °F)
for Pi=242 mW, Ii=76 mA, T552 °C (125.6 °F)
for Pi=242 mW, Ii=76 mA, T4-T152 °C (125.6 °F)
Equipment protection level Da
CE marking[*PD-Z02585A*]
ATEX marking II 1D Ex ia IIIC T135°C Da The Ex-related marking can also be printed on the enclosed label.
StandardsEN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection Intrinsic safety Use is restricted to the following stated conditions
Appropriate typeNCB8-18GM...-N0...
Effective internal capacitancemax. 120 nF A cable length of 10 m is considered.
Effective internal inductancemax. 50 µ,H , a cable length of 10 m is considered.
Maximum permissible ambient temperature Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the surface temperature, and the effective internal reactance values can be found on the EC-type-examination certificate. The maximum permissible ambient temperature of the data sheet must be noted, in addition, the lower of the two values must be maintained.
General information
Use in the hazardous areasee instruction manuals
Category1G, 2G, 3G, 1D