We are not the manufacturer, authorised distributor or authorised representative of the Pepperl+Fuchs brand in Australia. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Pepperl+Fuchs
Country
Germany
Name
NCB4-12GM40-N0
Part number
181086
Type
Inductive sensor
Description
Inductive sensor NCB4-12GM40-N0
Stock availability:
On request
If you require NCB4-12GM40-N0 181086 from manufacturer Pepperl+Fuchs, please contact FAMAGA.
For more than 10 years our specialists supply spare parts for the upgrading and maintenance of various types of technical equipment from all over the world. Over 700 orders from clients from countries of near and far abroad are in service daily. Developed partner network makes it possible to immediately implement order for Pepperl+Fuchs NCB4-12GM40-N0, while the customer does not have to spend more than planned amount.
Geography of deliveries includes Europe, Africa, America and Asia. Australia, India, Indonesia, United States, Costa Rica, South Korea, Ecuador, Belgium, Canada, Pakistan, Lesotho, Hungary, Peru, San Marino, Bulgaria, Brunei, Grenada, Sweden, Mozambique, Namibia, Liberia, Antigua and Barbuda, Saudi Arabia, Comoros, Slovakia, Uzbekistan, Panama, Togo, Eswatini, Bahamas, Montenegro, Seychelles, Kyrgyzstan, Ethiopia, Vietnam, Gambia, Cameroon, Armenia, Kiribati, Mauritania, Macedonia, Luxembourg, Bhutan, Switzerland, United Arab Emirates, Nepal, South Africa, Swaziland, Oman, Italy, Djibouti, Central African Republic, Colombia, Argentina, Netherlands, Germany, Barbados There is no restrictions on the size and mass of the cargo. We offer different delivery options so that a client can choose suitable balance between cost and delivery time.
Company`s fundamental rule of operation is transparency, which includes every sphere of activity. Customers get exceptionally high-quality products, to which relevant documentation from the manufacturer is available. All repair parts and equipment are original, likelihood of counterfeits are excluded. For permanent partners there are bonus programs and they are valid great deals.
Become an orderer from FAMAGA, get equipment with no delays and at profitable price. Fill in information in the order form on the website. Our specialist will contact you to specify details. Inquiries are also accepted by phone.
General specifications | ||
---|---|---|
Switching function | Normally closed (NC) | |
Output type | NAMUR | |
Rated operating distance | 4 mm | |
Installation | flush | |
Assured operating distance | 0 ... 3.24 mm | |
Actual operating distance | 3.6 ... 4.4 mm typ. | |
Reduction factor rAl | 0.41 | |
Reduction factor rCu | 0.39 | |
Reduction factor r304 | 0.78 | |
Output type | 2-wire | |
Nominal ratings | ||
Nominal voltage | 8.2 V (Ri approx. 1 k&Omega,) | |
Switching frequency | 0 ... 1500 Hz | |
Hysteresis | 1 ... 15 typ. 5 % | |
Reverse polarity protection | reverse polarity protected | |
Short-circuit protection | yes | |
Suitable for 2:1 technology | yes , Reverse polarity protection diode not required | |
Current consumption | ||
Measuring plate not detected | min. 2.2 mA | |
Measuring plate detected | &le, 1 mA | |
Switching state indicator | all direction LED, yellow | |
Functional safety related parameters | ||
MTTFd | 3010 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Compliance with standards and directives | ||
Standard conformity | ||
NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
Electromagnetic compatibility | NE 21:2007 | |
Standards | EN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 | |
Approvals and certificates | ||
EAC conformity | TR CU 012/2011 | |
FM approval | ||
Control drawing | 116-0165 | |
UL approval | ||
Ordinary Location | E87056 | |
Hazardous Location | E501628 | |
Control drawing | 116-0452 | |
CSA approval | cCSAus Listed, General Purpose | |
CCC approval | CCC approval / marking not required for products rated &le,36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) | |
Storage temperature | -40 ... 100 °C (-40 ... 212 °F) | |
Mechanical specifications | ||
Connection type | cable PVC , 2 m | |
Core cross-section | 0.34 mm2 | |
Housing material | Stainless steel 1.4305 / AISI 303 | |
Sensing face | PBT | |
Degree of protection | IP66 / IP67 | |
Cable | ||
Cable diameter | 4.8 mm ± 0.2 mm | |
Bending radius | > 10 x cable diameter | |
Equipment protection level Ga | ||
CE marking | [*PD-Z02585A*] | |
ATEX marking | II 1G Ex ia IIC T6&hellip,T1 Ga The Ex-related marking can also be printed on the enclosed label. | |
Standards | EN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection Intrinsic safety Use is restricted to the following stated conditions | |
Appropriate type | NCB4-12GM...-N0... | |
Effective internal capacitance | max. 120 nF , a cable length of 10 m is considered. | |
Effective internal inductance | max. 50 µ,H , a cable length of 10 m is considered. | |
Ambient temperature | Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EC-type examination certificate. Note: Use the temperature table for category 1 !!! The 20 % reduction in accordance with EN 1127-1 has already been applied to the temperature table for category 1. | |
Equipment protection level Gb | ||
CE marking | [*PD-Z02585A*] | |
ATEX marking | II 1G Ex ia IIC T6&hellip,T1 Ga The Ex-significant identification is on the enclosed adhesive label | |
Standards | EN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection Intrinsic safety Use is restricted to the following stated conditions | |
Appropriate type | NCB4-12GM...-N0... | |
Effective internal capacitance | max. 120 nF , a cable length of 10 m is considered. | |
Effective internal inductance | max. 50 µ,H , a cable length of 10 m is considered. | |
Maximum permissible ambient temperature | Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EC-type examination certificate. | |
Equipment protection level Gc (ic) | ||
Certificate | PF 13 CERT 2895 X | |
CE marking | [*PD-Z02586A*] | |
ATEX marking | II 3G Ex ic IIC T6&hellip,T1 Gc The Ex-significant identification is on the enclosed adhesive label | |
Standards | EN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection category ic Use is restricted to the following stated conditions | |
Effective internal capacitance | max. 120 nF , a cable length of 10 m is considered. | |
Effective internal inductance | max. 50 µ,H , A cable length of 10 m is considered. | |
Special conditions | ||
for Pi=34 mW, Ii=25 mA, T6 | 74 °C (165.2 °F) | |
for Pi=34 mW, Ii=25 mA, T5 | 89 °C (192.2 °F) | |
for Pi=34 mW, Ii=25 mA, T4-T1 | 100 °C (212 °F) | |
for Pi=64 mW, Ii=25 mA, T6 | 69 °C (156.2 °F) | |
for Pi=64 mW, Ii=25 mA, T5 | 84 °C (183.2 °F) | |
for Pi=64 mW, Ii=25 mA, T4-T1 | 100 °C (212 °F) | |
for Pi=169 mW, Ii=52 mA, T6 | 51 °C (123.8 °F) | |
for Pi=169 mW, Ii=52 mA, T5 | 66 °C (150.8 °F) | |
for Pi=169 mW, Ii=52 mA, T4-T1 | 74 °C (165.2 °F) | |
for Pi=242 mW, Ii=76 mA, T6 | 39 °C (102.2 °F) | |
for Pi=242 mW, Ii=76 mA, T5 | 52 °C (125.6 °F) | |
for Pi=242 mW, Ii=76 mA, T4-T1 | 52 °C (125.6 °F) | |
Equipment protection level Gc (nL) | ||
Standard conformity | EN 60079-15:2003 Ignition protection category n Use is restricted to the following stated conditions | |
Effective internal capacitance Ci | max. 120 nF , a cable length of 10 m is considered. | |
Effective internal inductance Li | max. 50 µ,H , A cable length of 10 m is considered. | |
General | The apparatus has to be operated according to the appropriate data in the data sheet and in this instruction manual. The data stated in the data sheet are restricted by this operating instruction! The special conditions must be observed! The ATEX Directive applies only to the use of apparatus under atmospheric conditions. If you use the device outside atmospheric conditions, consider that the permissible safety parameters should be reduced. | |
Special conditions | ||
for Pi=34 mW, Ii=25 mA, T6 | 74 °C (165.2 °F) | |
for Pi=34 mW, Ii=25 mA, T5 | 89 °C (192.2 °F) | |
for Pi=34 mW, Ii=25 mA, T4-T1 | 100 °C (212 °F) | |
for Pi=64 mW, Ii=25 mA, T6 | 69 °C (156.2 °F) | |
for Pi=64 mW, Ii=25 mA, T5 | 84 °C (183.2 °F) | |
for Pi=64 mW, Ii=25 mA, T4-T1 | 100 °C (212 °F) | |
for Pi=169 mW, Ii=52 mA, T6 | 51 °C (123.8 °F) | |
for Pi=169 mW, Ii=52 mA, T5 | 66 °C (150.8 °F) | |
for Pi=169 mW, Ii=52 mA, T4-T1 | 74 °C (165.2 °F) | |
for Pi=242 mW, Ii=76 mA, T6 | 39 °C (102.2 °F) | |
for Pi=242 mW, Ii=76 mA, T5 | 52 °C (125.6 °F) | |
for Pi=242 mW, Ii=76 mA, T4-T1 | 52 °C (125.6 °F) | |
Equipment protection level Da | ||
CE marking | [*PD-Z02585A*] | |
ATEX marking | II 1D Ex ia IIIC T135°C Da The Ex-related marking can also be printed on the enclosed label. | |
Standards | EN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection Intrinsic safety Use is restricted to the following stated conditions | |
Appropriate type | NCB4-12GM...-N0... | |
Effective internal capacitance | max. 120 nF A cable length of 10 m is considered. | |
Effective internal inductance | max. 50 µ,H , a cable length of 10 m is considered. | |
Maximum permissible ambient temperature | Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the surface temperature, and the effective internal reactance values can be found on the EC-type-examination certificate. The maximum permissible ambient temperature of the data sheet must be noted, in addition, the lower of the two values must be maintained. | |
Equipment protection level Dc | ||
CE marking | [*PD-Z02585A*] | |
ATEX marking | II 3D IP67 T 111 °C (231.8 °F) X | |
Standards | EN 50281-1-1 Protection via housing Use is restricted to the following stated conditions | |
Special conditions | ||
Maximum heating (Temperature rise) | Values can be obtained from the following list, depending on the max. operating voltage Ub max and the minimum series resistance Rv. | |
at UBmax=9 V, RV=562 &Omega, | 11 K | |
using an amplifier in accordance with EN 60947-5-6 | 11 K | |
General information | ||
Scope of delivery | 2 self locking nuts in scope of delivery | |
Use in the hazardous area | see instruction manuals | |
Category | 1G, 2G, 3G, 1D |