Inductive sensor NBB2-8GM40-E2-V1-3G-3D Pepperl+Fuchs 129853
Inductive sensor NBB2-8GM40-E2-V1-3G-3D Pepperl+Fuchs 129853

We are not the manufacturer, authorised distributor or authorised representative of the Pepperl+Fuchs brand in Australia. The private labels and part numbers shown on this website are the property of their respective owners.

Pepperl+Fuchs NBB2-8GM40-E2-V1-3G-3D 129853

Manufacturer

Pepperl+Fuchs

Country

Germany

Name

NBB2-8GM40-E2-V1-3G-3D

Part number

129853

Type

Inductive sensor

Description

Inductive sensor NBB2-8GM40-E2-V1-3G-3D

Stock availability:

On request

Price: On request

Order

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications NBB2-8GM40-E2-V1-3G-3D 129853

If you require NBB2-8GM40-E2-V1-3G-3D 129853 from manufacturer Pepperl+Fuchs, please contact FAMAGA.

For more than 9 years our employees supply repair parts for the upgrade and maintenance different kinds of technical equipment from all over the world. Over 600 orders from clients from various countries are in service daily. Developed partner network provides an opportunity to execute without delay order for Pepperl+Fuchs NBB2-8GM40-E2-V1-3G-3D, while the buyer does not have to go over budget.

Geography of deliveries involves Europe, Asia, Africa and America. There is no restrictions on the size and weight of the cargo. We developed different delivery options so that a buyer can choose suitable balance between cost and delivery time.

Company`s fundamental rule of operation is transparency, which includes every direction of activity. Customers get exceptionally high-quality products, to which factory warranty applies. All repair parts and equipment are original, risk of presence of counterfeits are excluded. For permanent partners there are bonus programs and they are valid affordable prices.

Become an orderer from FAMAGA, get goods with no delay and at profitable price. Fill in information in the order form on the website. Our specialist will contact you to specify details. Inquiries are also accepted by phone.

Features NBB2-8GM40-E2-V1-3G-3D 129853

General specifications
Switching functionNormally open (NO)
Output typePNP
Rated operating distance2 mm
Installationflush
Output polarityDC
Assured operating distance0 ... 1.62 mm
Reduction factor rAl 0.45
Reduction factor rCu 0.35
Reduction factor r304 0.75
Output type3-wire
Nominal ratings
Operating voltage10 ... 30 V DC
Switching frequency0 ... 1500 Hz
Hysteresistyp. 5 %
Reverse polarity protectionreverse polarity protected
Short-circuit protectionpulsing
Voltage drop&le, 3 V
Operating current0 ... 100 mA
Off-state current0 ... 0.5 mA typ. 0.1 µ,A
No-load supply current&le, 15 mA
Time delay before availability&le, 5 ms
Switching state indicatorMultihole-LED, yellow
Compliance with standards and directives
Standard conformity
StandardsEN 60947-5-2:2007 IEC 60947-5-2:2007
Approvals and certificates
UL approvalcULus Listed, General Purpose
CSA approvalcCSAus Listed, General Purpose
CCC approvalCCC approval / marking not required for products rated &le,36 V
Ambient conditions
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Mechanical specifications
Connection typeConnector plug M12 x 1 , 4-pin
Housing materialbrass, nickel-plated
Sensing faceLCP
Degree of protectionIP67
Equipment protection level Gc (nA)
CertificatePF 15CERT3754 X
CE marking[*PD-Z02586A*]
ATEX marking II 3G Ex nA IIC T6 Gc The Ex-related marking can also be printed on the enclosed label.
StandardsEN 60079-0:2012+A11:2013, EN 60079-15:2010 Ignition protection category n Use is restricted to the following stated conditions
Special conditions
Maximum operating current ILThe maximum permissible load current must be restricted to the values given in the following list. High load currents and load short-circuits are not permitted.
Maximum operating voltage UBmaxThe maximum permissible operating voltage UB max is restricted to the values in the following list. Tolerances are not permissible.
Maximum permissible ambient temperature TUmaxdependant of the load current IL and the max. operating voltage UBmax Information can be taken from the following list.
at UBmax=30 V, IL=100 mA49 °C (120.2 °F)
at UBmax=30 V, IL=50 mA51 °C (123.8 °F)
Equipment protection level Dc
CE marking[*PD-Z02586A*]
ATEX marking II 3D IP67 T 90 °C (194 °F) X The Ex-significant identification is on the enclosed adhesive label
StandardsEN 50281-1-1 Protection via housing Use is restricted to the following stated conditions
Special conditions
Maximum heating (Temperature rise)dependant of the load current IL and the max. operating voltage UBmax Information can be taken from the following list. The maximum surface temperature at maximum ambient temperature is given in the Ex identification of the apparatus.
at UBmax=30 V, IL=100 mA20 K
at UBmax=30 V, IL=50 mA19 K
Equipment protection level Dc (tc)
CE marking[*PD-Z02586A*]
ATEX marking II 3D Ex tc IIIC T80°C Dc The Ex-related marking can also be printed on the enclosed label.
StandardsEN 60079-0:2012+A11:2013, EN 60079-31:2014 Protection by enclosure tc Some of the information in this instruction manual is more specific than the information provided in the datasheet.
GeneralThe corresponding datasheets, declarations of conformity, EC-type examination certificates, certifications, and control drawings, where applicable (see datasheets), form an integral part of this document. These documents can be found at www.pepperl-fuchs.com. The maximum surface temperature of the device was determined without a layer of dust on the apparatus. Some of the information in this instruction manual is more specific than the information provided in the datasheet.
Special conditions
Maximum permissible ambient temperature TUmaxdependant of the load current IL and the max. operating voltage UBmax Information can be taken from the following list.
at UBmax=30 V, IL=100 mA49 °C (120.2 °F)
at UBmax=30 V, IL=50 mA51 °C (123.8 °F)
Equipment protection level Dc (tD)
GeneralThe apparatus has to be operated according to the appropriate data in the data sheet and in this instruction manual. The maximum surface temperature has been determined in accordance with method A without a dust layer on the equipment. The data stated in the data sheet are restricted by this operating instruction! The special conditions must be adhered to!
Special conditions
Maximum permissible ambient temperature TUmaxdependant of the load current IL and the max. operating voltage UBmax Information can be taken from the following list.
at UBmax=30 V, IL=100 mA49 °C (120.2 °F)
at UBmax=30 V, IL=50 mA51 °C (123.8 °F)
General information
Use in the hazardous areasee instruction manuals
Category3G, 3D