We are not the manufacturer, authorised distributor or authorised representative of the Pepperl+Fuchs brand in Australia. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Pepperl+Fuchs
Country
Germany
Name
NBB2-8GM40-E2-V1-3G-3D
Part number
129853
Type
Inductive sensor
Description
Inductive sensor NBB2-8GM40-E2-V1-3G-3D
Stock availability:
On request
If you require NBB2-8GM40-E2-V1-3G-3D 129853 from manufacturer Pepperl+Fuchs, please contact FAMAGA.
For more than 9 years our employees supply repair parts for the upgrade and maintenance different kinds of technical equipment from all over the world. Over 600 orders from clients from various countries are in service daily. Developed partner network provides an opportunity to execute without delay order for Pepperl+Fuchs NBB2-8GM40-E2-V1-3G-3D, while the buyer does not have to go over budget.
Geography of deliveries involves Europe, Asia, Africa and America. Australia, India, Indonesia, United States, Thailand, Czech Republic, Latvia, Pakistan, San Marino, Myanmar, Samoa, Bulgaria, Central African Republic, Kyrgyzstan, Senegal, Bahrain, Ethiopia, Madagascar, Portugal, Saudi Arabia, Yemen, Turkey, Cape Verde, Swaziland, Armenia, Panama, Mongolia, Djibouti, Peru, Gambia, Liechtenstein, Gabon, Slovakia, Denmark, Lithuania, Albania, Netherlands, Morocco, Dominica, Switzerland, The Gambia, Guatemala, Burundi, Belize, Afghanistan, Côte d\'Ivoire, Nepal, Togo, Luxembourg, Syria, South Korea, Venezuela, Papua New Guinea, Singapore, Guinea-Bissau, China, Eswatini, Honduras, Guyana, Colombia, Philippines, Benin There is no restrictions on the size and weight of the cargo. We developed different delivery options so that a buyer can choose suitable balance between cost and delivery time.
Company`s fundamental rule of operation is transparency, which includes every direction of activity. Customers get exceptionally high-quality products, to which factory warranty applies. All repair parts and equipment are original, risk of presence of counterfeits are excluded. For permanent partners there are bonus programs and they are valid affordable prices.
Become an orderer from FAMAGA, get goods with no delay and at profitable price. Fill in information in the order form on the website. Our specialist will contact you to specify details. Inquiries are also accepted by phone.
General specifications | ||
---|---|---|
Switching function | Normally open (NO) | |
Output type | PNP | |
Rated operating distance | 2 mm | |
Installation | flush | |
Output polarity | DC | |
Assured operating distance | 0 ... 1.62 mm | |
Reduction factor rAl | 0.45 | |
Reduction factor rCu | 0.35 | |
Reduction factor r304 | 0.75 | |
Output type | 3-wire | |
Nominal ratings | ||
Operating voltage | 10 ... 30 V DC | |
Switching frequency | 0 ... 1500 Hz | |
Hysteresis | typ. 5 % | |
Reverse polarity protection | reverse polarity protected | |
Short-circuit protection | pulsing | |
Voltage drop | &le, 3 V | |
Operating current | 0 ... 100 mA | |
Off-state current | 0 ... 0.5 mA typ. 0.1 µ,A | |
No-load supply current | &le, 15 mA | |
Time delay before availability | &le, 5 ms | |
Switching state indicator | Multihole-LED, yellow | |
Compliance with standards and directives | ||
Standard conformity | ||
Standards | EN 60947-5-2:2007 IEC 60947-5-2:2007 | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
CCC approval | CCC approval / marking not required for products rated &le,36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Mechanical specifications | ||
Connection type | Connector plug M12 x 1 , 4-pin | |
Housing material | brass, nickel-plated | |
Sensing face | LCP | |
Degree of protection | IP67 | |
Equipment protection level Gc (nA) | ||
Certificate | PF 15CERT3754 X | |
CE marking | [*PD-Z02586A*] | |
ATEX marking | II 3G Ex nA IIC T6 Gc The Ex-related marking can also be printed on the enclosed label. | |
Standards | EN 60079-0:2012+A11:2013, EN 60079-15:2010 Ignition protection category n Use is restricted to the following stated conditions | |
Special conditions | ||
Maximum operating current IL | The maximum permissible load current must be restricted to the values given in the following list. High load currents and load short-circuits are not permitted. | |
Maximum operating voltage UBmax | The maximum permissible operating voltage UB max is restricted to the values in the following list. Tolerances are not permissible. | |
Maximum permissible ambient temperature TUmax | dependant of the load current IL and the max. operating voltage UBmax Information can be taken from the following list. | |
at UBmax=30 V, IL=100 mA | 49 °C (120.2 °F) | |
at UBmax=30 V, IL=50 mA | 51 °C (123.8 °F) | |
Equipment protection level Dc | ||
CE marking | [*PD-Z02586A*] | |
ATEX marking | II 3D IP67 T 90 °C (194 °F) X The Ex-significant identification is on the enclosed adhesive label | |
Standards | EN 50281-1-1 Protection via housing Use is restricted to the following stated conditions | |
Special conditions | ||
Maximum heating (Temperature rise) | dependant of the load current IL and the max. operating voltage UBmax Information can be taken from the following list. The maximum surface temperature at maximum ambient temperature is given in the Ex identification of the apparatus. | |
at UBmax=30 V, IL=100 mA | 20 K | |
at UBmax=30 V, IL=50 mA | 19 K | |
Equipment protection level Dc (tc) | ||
CE marking | [*PD-Z02586A*] | |
ATEX marking | II 3D Ex tc IIIC T80°C Dc The Ex-related marking can also be printed on the enclosed label. | |
Standards | EN 60079-0:2012+A11:2013, EN 60079-31:2014 Protection by enclosure tc Some of the information in this instruction manual is more specific than the information provided in the datasheet. | |
General | The corresponding datasheets, declarations of conformity, EC-type examination certificates, certifications, and control drawings, where applicable (see datasheets), form an integral part of this document. These documents can be found at www.pepperl-fuchs.com. The maximum surface temperature of the device was determined without a layer of dust on the apparatus. Some of the information in this instruction manual is more specific than the information provided in the datasheet. | |
Special conditions | ||
Maximum permissible ambient temperature TUmax | dependant of the load current IL and the max. operating voltage UBmax Information can be taken from the following list. | |
at UBmax=30 V, IL=100 mA | 49 °C (120.2 °F) | |
at UBmax=30 V, IL=50 mA | 51 °C (123.8 °F) | |
Equipment protection level Dc (tD) | ||
General | The apparatus has to be operated according to the appropriate data in the data sheet and in this instruction manual. The maximum surface temperature has been determined in accordance with method A without a dust layer on the equipment. The data stated in the data sheet are restricted by this operating instruction! The special conditions must be adhered to! | |
Special conditions | ||
Maximum permissible ambient temperature TUmax | dependant of the load current IL and the max. operating voltage UBmax Information can be taken from the following list. | |
at UBmax=30 V, IL=100 mA | 49 °C (120.2 °F) | |
at UBmax=30 V, IL=50 mA | 51 °C (123.8 °F) | |
General information | ||
Use in the hazardous area | see instruction manuals | |
Category | 3G, 3D |