Inductive sensor NCB40-FP-A2-P1-3G-3D Pepperl+Fuchs 129431
Inductive sensor NCB40-FP-A2-P1-3G-3D Pepperl+Fuchs 129431

We are not the manufacturer, authorised distributor or authorised representative of the Pepperl+Fuchs brand in Australia. The private labels and part numbers shown on this website are the property of their respective owners.

Pepperl+Fuchs NCB40-FP-A2-P1-3G-3D 129431

Manufacturer

Pepperl+Fuchs

Country

Germany

Name

NCB40-FP-A2-P1-3G-3D

Part number

129431

Type

Inductive sensor

Description

Inductive sensor NCB40-FP-A2-P1-3G-3D

Stock availability:

On request

Price: On request

Order

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications NCB40-FP-A2-P1-3G-3D 129431

If you require NCB40-FP-A2-P1-3G-3D 129431 from manufacturer Pepperl+Fuchs, please contact FAMAGA.

For more than 10 years our managers supply repair parts for the renovation and maintenance different kinds of manufacturing equipment from all parts of the planet. Over 750 orders from clients from various countries are arrived daily. Developed partner network allows you to quickly execute order for Pepperl+Fuchs NCB40-FP-A2-P1-3G-3D, while the client does not have to worry about extra costs.

Geography of deliveries includes Europe, America, Asia and Africa. There is no restrictions on the size and weight of the cargo. We offer different delivery options so that a client can choose suitable balance between cost and delivery time.

Company`s main postulate is transparency, which covers every direction of activity. Clients get top-class spare parts and equipment, to which all necessary certificates are available. All repair parts and equipment are original, risk of presence of counterfeits are excluded. For permanent partners there are bonus programs and they are valid great deals.

Become an orderer from FAMAGA, get goods fast and at profitable price. Fill in the order form on the website. Our employee will contact you to discuss details. Orders are also accepted by phone.

Features NCB40-FP-A2-P1-3G-3D 129431

General specifications
Switching functioncomplementary
Output typePNP
Rated operating distance40 mm
Installationflush
Output polarityDC
Assured operating distance0 ... 32.4 mm
Reduction factor rAl 0.25
Reduction factor rCu 0.23
Reduction factor r304 0.85
Output type4-wire
Nominal ratings
Operating voltage10 ... 60 V DC
Switching frequency0 ... 80 Hz
Hysteresistyp. 3 %
Reverse polarity protectionreverse polarity protected
Voltage drop&le, 3 V
Operating current0 ... 200 mA
Off-state current0 ... 0.5 mA
No-load supply current&le, 20 mA
Time delay before availability&le, 300 ms
Operating voltage indicatorLED, green
Switching state indicatorLED, yellow
Functional safety related parameters
MTTFd630 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Compliance with standards and directives
Standard conformity
StandardsEN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012
Approvals and certificates
UL approvalcULus Listed, General Purpose
CSA approvalcCSAus Listed, General Purpose
CCC approvalCertified by China Compulsory Certification (CCC)
Ambient conditions
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Mechanical specifications
Connection typescrew terminals
Information for connectionA maximum of two conductors with the same core cross section may be mounted on one terminal connection! tightening torque 1.2 Nm + 10 %
Core cross-sectionup to 2.5 mm2
Minimum core cross-sectionwithout wire end ferrule 0.5 mm2 , with connector sleeves 0.34 mm2
Maximum core cross-sectionwithout wire end ferrule 2.5 mm2 , with connector sleeves 1.5 mm2
Housing materialPBT
Sensing facePBT
Housing basePBT
Degree of protectionIP68
Equipment protection level Gc (nA)
CertificatePF 15CERT3754 X
CE marking[*PD-Z02586A*]
ATEX marking II 3G Ex nA IIC T6 Gc The Ex-related marking can also be printed on the enclosed label.
StandardsEN 60079-0:2012+A11:2013, EN 60079-15:2010 Ignition protection category n Use is restricted to the following stated conditions
Special conditions
Maximum operating current ILThe maximum permissible load current must be restricted to the values given in the following list. High load currents and load short-circuits are not permitted.
Maximum operating voltage UBmaxThe maximum permissible operating voltage UB max is restricted to the values in the following list. Tolerances are not permissible.
Maximum permissible ambient temperature TUmaxdependant of the load current IL and the max. operating voltage UBmax Information can be taken from the following list.
at UBmax=60 V, IL=200 mA44 °C (111.2 °F)
at UBmax=60 V, IL=100 mA45 °C (113 °F)
at UBmax=60 V, IL=50 mA48 °C (118.4 °F)
at UBmax=60 V, IL=25 mA48 °C (118.4 °F)
at UBmax=30 V, IL=200 mA51 °C (123.8 °F)
at UBmax=30 V, IL=100 mA55 °C (131 °F)
at UBmax=30 V, IL=50 mA56 °C (132.8 °F)
at UBmax=30 V, IL=25 mA57 °C (134.6 °F)
Equipment protection level Dc
CE marking[*PD-Z02586A*]
ATEX marking II 3D IP67 T 96 °C (204.8 °F) X
StandardsEN 50281-1-1 Protection via housing Use is restricted to the following stated conditions
Special conditions
Maximum heating (Temperature rise)dependant of the load current IL and the max. operating voltage UBmax Information can be taken from the following list. The maximum surface temperature at maximum ambient temperature is given in the Ex identification of the apparatus.
at UBmax=60 V, IL=200 mA26 K
at UBmax=60 V, IL=100 mA25 K
at UBmax=60 V, IL=50 mA22 K
at UBmax=60 V, IL=25 mA22 K
at UBmax=30 V, IL=200 mA19 K
at UBmax=30 V, IL=100 mA15 K
at UBmax=30 V, IL=50 mA13 K
Equipment protection level Dc (tc)
CE marking[*PD-Z02586A*]
ATEX marking II 3D Ex tc IIIC T80°C Dc The Ex-related marking can also be printed on the enclosed label.
StandardsEN 60079-0:2012+A11:2013, EN 60079-31:2014 Protection by enclosure tc Some of the information in this instruction manual is more specific than the information provided in the datasheet.
GeneralThe corresponding datasheets, declarations of conformity, EC-type examination certificates, certifications, and control drawings, where applicable (see datasheets), form an integral part of this document. These documents can be found at www.pepperl-fuchs.com. The maximum surface temperature of the device was determined without a layer of dust on the apparatus. Some of the information in this instruction manual is more specific than the information provided in the datasheet.
Special conditions
Maximum permissible ambient temperature TUmaxdependant of the load current IL and the max. operating voltage UBmax Information can be taken from the following list.
at UBmax=60 V, IL=200 mA44 °C (111.2 °F)
at UBmax=60 V, IL=100 mA45 °C (113 °F)
at UBmax=60 V, IL=50 mA48 °C (118.4 °F)
at UBmax=60 V, IL=25 mA48 °C (118.4 °F)
at UBmax=30 V, IL=200 mA51 °C (123.8 °F)
at UBmax=30 V, IL=100 mA55 °C (131 °F)
at UBmax=30 V, IL=50 mA56 °C (132.8 °F)
General information
Use in the hazardous areasee instruction manuals
Category3G, 3D