Inductive sensor NJ2-11-N-G-Y129365 Pepperl+Fuchs 129365
Inductive sensor NJ2-11-N-G-Y129365 Pepperl+Fuchs 129365

We are not the manufacturer, authorised distributor or authorised representative of the Pepperl+Fuchs brand in Australia. The private labels and part numbers shown on this website are the property of their respective owners.

Pepperl+Fuchs NJ2-11-N-G-Y129365 129365

Manufacturer

Pepperl+Fuchs

Country

Germany

Name

NJ2-11-N-G-Y129365

Part number

129365

Type

Inductive sensor

Description

Inductive sensor NJ2-11-N-G-Y129365

Stock availability:

On request

Price: On request

Order

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications NJ2-11-N-G-Y129365 129365

If you require NJ2-11-N-G-Y129365 129365 from manufacturer Pepperl+Fuchs, please contact FAMAGA.

For more than 9 years our managers supply spare parts for the upgrade and maintenance different kinds of technical equipment from all over the world. Over 650 orders from clients from countries of near and far abroad are arrived daily. Developed partner network provides an opportunity to execute without delay order for Pepperl+Fuchs NJ2-11-N-G-Y129365, while the buyer does not have to go over budget.

Geography of deliveries includes Europe, Asia, America and Africa. There is no restrictions on the size and mass of the cargo. We developed different delivery options so that a buyer can choose suitable balance between cost and delivery time.

Company`s main postulate is transparency, which involves every segment of activity. Customers get exceptionally high-quality products, to which factory warranty applies. All repair parts and equipment are original, likelihood of counterfeits are excluded. For permanent customers there are bonus programs and they are valid affordable prices.

Become an orderer from FAMAGA, get machine-tools with no delays and at beneficial price. Fill in information in the order form on the website. Our specialist will contact you to specify details. Orders are also accepted by phone.

Features NJ2-11-N-G-Y129365 129365

General specifications
Switching functionNormally closed (NC)
Output typeNAMUR
Rated operating distance2 mm
Installationflush
Assured operating distance0 ... 1.62 mm
Actual operating distance1.8 ... 2.2 mm
Reduction factor rAl 0.4
Reduction factor rCu 0.3
Reduction factor r304 0.85
Output type2-wire
Nominal ratings
Nominal voltage8 V
Switching frequency0 ... 3000 Hz
Hysteresis0.5 ... 3.5 typ. 2 %
Current consumption
Measuring plate not detectedmin. 3 mA
Measuring plate detected&le, 1 mA
Functional safety related parameters
MTTFd5887 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Compliance with standards and directives
Standard conformity
NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999
StandardsEN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012
Approvals and certificates
UL approval
Ordinary LocationE87056
Hazardous LocationE501628
Control drawing116-0452
Ambient conditions
Ambient temperature-25 ... 100 °C (-13 ... 212 °F)
Mechanical specifications
Connection typecable PVC , 5 m
Core cross-section0.34 mm2
Housing materialStainless steel 1.4305 / AISI 303
Sensing facePVDF
Degree of protectionIP68
Cable
Bending radius> 10 x cable diameter
Equipment protection level Ga
CE marking[*PD-Z02585A*]
ATEX marking II 1G Ex ia IIC T6&hellip,T1 Ga The Ex-related marking can also be printed on the enclosed label.
StandardsEN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection Intrinsic safety Use is restricted to the following stated conditions
Appropriate typeNJ 2-11-N-G...
Effective internal capacitancemax. 30 nF , a cable length of 10 m is considered.
Effective internal inductancemax. 50 µ,H , a cable length of 10 m is considered.
Ambient temperatureDetails of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EC-type examination certificate. Note: Use the temperature table for category 1 !!! The 20 % reduction in accordance with EN 1127-1 has already been applied to the temperature table for category 1.
Equipment protection level Gb
CE marking[*PD-Z02585A*]
ATEX marking II 1G Ex ia IIC T6&hellip,T1 Ga The Ex-significant identification is on the enclosed adhesive label
StandardsEN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection Intrinsic safety Use is restricted to the following stated conditions
Appropriate typeNJ 2-11-N-G...
Effective internal capacitancemax. 30 nF , a cable length of 10 m is considered.
Effective internal inductancemax. 50 µ,H , a cable length of 10 m is considered.
Maximum permissible ambient temperatureDetails of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EC-type examination certificate.
Equipment protection level Da
CE marking[*PD-Z02585A*]
ATEX marking II 1D Ex ia IIIC T135°C Da The Ex-related marking can also be printed on the enclosed label.
StandardsEN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection Intrinsic safety Use is restricted to the following stated conditions
Appropriate typeNJ 2-11-N-G...
Effective internal capacitancemax. 30 nF , a cable length of 10 m is considered.
Effective internal inductancemax. 50 µ,H , a cable length of 10 m is considered.
Maximum permissible ambient temperature Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the surface temperature, and the effective internal reactance values can be found on the EC-type-examination certificate. The maximum permissible ambient temperature of the data sheet must be noted, in addition, the lower of the two values must be maintained.
General information
Use in the hazardous areasee instruction manuals
Category1G, 2G, 1D