Manufacturer
Pepperl+Fuchs
Country
Germany
Name
NCB1,5-8GM25-N0-V1
Part number
128867
Type
Inductive sensor
Description
Inductive sensor NCB1,5-8GM25-N0-V1
Stock availability:
On request
If you require NCB1,5-8GM25-N0-V1 128867 from manufacturer Pepperl+Fuchs, please contact FAMAGA.
For more than 8 years our employees supply spare parts for the renovation and maintenance of various types of industrial equipment from all corners of the earth. Over 700 orders from clients from different countries are in service daily. Developed partner network allows you to quickly execute order for Pepperl+Fuchs NCB1,5-8GM25-N0-V1, while the customer does not have to spend more than planned amount.
Geography of deliveries involves Europe, America, Africa and Asia. Australia, India, Indonesia, United States, Cameroon, Tajikistan, Liberia, Iceland, Belize, Armenia, Colombia, Estonia, Kiribati, Slovenia, Venezuela, Czech Republic, Suriname, Belgium, Slovakia, Japan, Senegal, Bulgaria, San Marino, Tanzania, Tonga, Brunei, Paraguay, Bahamas, Turkey, United Arab Emirates, Comoros, China, Nepal, Swaziland, Ethiopia, Chile, Syria, Luxembourg, Papua New Guinea, Vietnam, Mali, Benin, Mauritius, United Kingdom, South Korea, Lesotho, Côte d\'Ivoire, Bahrain, Gambia, Fiji, Oman, Myanmar, Panama, Iraq, France, Guinea-Bissau, Ghana, Argentina, Nicaragua, Guyana, Malawi There is no restrictions on the size and weight of the cargo. We offer different delivery options so that a customer can choose suitable balance between cost and delivery time.
Company`s fundamental rule of operation is transparency, which includes every sphere of activity. Clients get only high-quality products, to which relevant documentation from the manufacturer is available. All repair parts and equipment are original, likelihood of counterfeits are excluded. For permanent partners there are loyalty programs and they are valid special pricing.
Become an orderer from FAMAGA, get gear with no delay and at attractive price. Fill in the order form on the website. Manager will contact you to discuss nuances. Inquiries are also accepted by phone.
General specifications | ||
---|---|---|
Switching function | Normally closed (NC) | |
Output type | NAMUR | |
Rated operating distance | 1.5 mm | |
Installation | flush | |
Assured operating distance | 0 ... 1.215 mm | |
Actual operating distance | 1.35 ... 1.65 mm typ. | |
Reduction factor rAl | 0.22 | |
Reduction factor rCu | 0.19 | |
Reduction factor r304 | 0.65 | |
Output type | 2-wire | |
Nominal ratings | ||
Nominal voltage | 8.2 V (Ri approx. 1 k&Omega,) | |
Switching frequency | 0 ... 2000 Hz | |
Hysteresis | 1 ... 10 typ. 3 % | |
Reverse polarity protection | reverse polarity protected | |
Short-circuit protection | yes | |
Suitable for 2:1 technology | yes , Reverse polarity protection diode not required | |
Current consumption | ||
Measuring plate not detected | min. 3 mA | |
Measuring plate detected | &le, 1 mA | |
Switching state indicator | Multihole-LED, yellow | |
Functional safety related parameters | ||
MTTFd | 3430 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Compliance with standards and directives | ||
Standard conformity | ||
NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
Standards | EN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 | |
Approvals and certificates | ||
EAC conformity | TR CU 012/2011 | |
FM approval | ||
Control drawing | 116-0165 | |
UL approval | ||
Ordinary Location | E87056 | |
Hazardous Location | E501628 | |
Control drawing | 116-0452 | |
CSA approval | cCSAus Listed, General Purpose | |
CCC approval | CCC approval / marking not required for products rated &le,36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) | |
Storage temperature | -40 ... 100 °C (-40 ... 212 °F) | |
Mechanical specifications | ||
Connection type | Connector plug M12 x 1 , 4-pin | |
Housing material | Stainless steel 1.4305 / AISI 303 | |
Sensing face | LCP | |
Degree of protection | IP67 | |
Equipment protection level Ga | ||
CE marking | [*PD-Z02585A*] | |
ATEX marking | II 1G Ex ia IIC T6&hellip,T1 Ga The Ex-related marking can also be printed on the enclosed label. | |
Standards | EN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection Intrinsic safety Use is restricted to the following stated conditions | |
Appropriate type | NCB1,5...M...N0... | |
Effective internal capacitance | max. 90 nF , a cable length of 10 m is considered. | |
Effective internal inductance | max. 100 µ,H , a cable length of 10 m is considered. | |
Ambient temperature | Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EC-type examination certificate. Note: Use the temperature table for category 1 !!! The 20 % reduction in accordance with EN 1127-1 has already been applied to the temperature table for category 1. | |
Equipment protection level Gb | ||
CE marking | [*PD-Z02585A*] | |
ATEX marking | II 1G Ex ia IIC T6&hellip,T1 Ga The Ex-significant identification is on the enclosed adhesive label | |
Standards | EN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection Intrinsic safety Use is restricted to the following stated conditions | |
Appropriate type | NCB1,5...M...N0... | |
Effective internal capacitance | max. 90 nF , a cable length of 10 m is considered. | |
Effective internal inductance | max. 100 µ,H , a cable length of 10 m is considered. | |
Maximum permissible ambient temperature | Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EC-type examination certificate. | |
Equipment protection level Gc (ic) | ||
Certificate | PF 13 CERT 2895 X | |
CE marking | [*PD-Z02586A*] | |
ATEX marking | II 3G Ex ic IIC T6&hellip,T1 Gc The Ex-significant identification is on the enclosed adhesive label | |
Standards | EN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection category ic Use is restricted to the following stated conditions | |
Effective internal capacitance | max. 90 nF , a cable length of 10 m is considered. | |
Effective internal inductance | max. 100 µ,H , A cable length of 10 m is considered. | |
Special conditions | ||
for Pi=34 mW, Ii=25 mA, T6 | 55 °C (131 °F) | |
for Pi=34 mW, Ii=25 mA, T5 | 55 °C (131 °F) | |
for Pi=34 mW, Ii=25 mA, T4-T1 | 55 °C (131 °F) | |
for Pi=64 mW, Ii=25 mA, T6 | 55 °C (131 °F) | |
for Pi=64 mW, Ii=25 mA, T5 | 55 °C (131 °F) | |
for Pi=64 mW, Ii=25 mA, T4-T1 | 55 °C (131 °F) | |
for Pi=169 mW, Ii=52 mA, T6 | 41 °C (105.8 °F) | |
for Pi=169 mW, Ii=52 mA, T5 | 41 °C (105.8 °F) | |
for Pi=169 mW, Ii=52 mA, T4-T1 | 41 °C (105.8 °F) | |
for Pi=242 mW, Ii=76 mA, T6 | 29 °C (84.2 °F) | |
for Pi=242 mW, Ii=76 mA, T5 | 29 °C (84.2 °F) | |
for Pi=242 mW, Ii=76 mA, T4-T1 | 29 °C (84.2 °F) | |
Equipment protection level Da | ||
CE marking | [*PD-Z02585A*] | |
ATEX marking | II 1D Ex ia IIIC T135°C Da The Ex-related marking can also be printed on the enclosed label. | |
Standards | EN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection Intrinsic safety Use is restricted to the following stated conditions | |
Appropriate type | NCB1,5...M...N0... | |
Effective internal capacitance | max. 90 nF , a cable length of 10 m is considered. | |
Effective internal inductance | max. 100 µ,H , a cable length of 10 m is considered. | |
Maximum permissible ambient temperature | Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the surface temperature, and the effective internal reactance values can be found on the EC-type-examination certificate. The maximum permissible ambient temperature of the data sheet must be noted, in addition, the lower of the two values must be maintained. | |
General information | ||
Use in the hazardous area | see instruction manuals | |
Category | 1G, 2G, 1D |