Inductive sensor NCB1,5-6,5M25-N0-10M Pepperl+Fuchs 128866
Inductive sensor NCB1,5-6,5M25-N0-10M Pepperl+Fuchs 128866

We are not the manufacturer, authorised distributor or authorised representative of the Pepperl+Fuchs brand in Australia. The private labels and part numbers shown on this website are the property of their respective owners.

Pepperl+Fuchs NCB1,5-6,5M25-N0-10M 128866

Manufacturer

Pepperl+Fuchs

Country

Germany

Name

NCB1,5-6,5M25-N0-10M

Part number

128866

Type

Inductive sensor

Description

Inductive sensor NCB1,5-6,5M25-N0-10M

Stock availability:

On request

Price: On request

Order

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications NCB1,5-6,5M25-N0-10M 128866

If you require NCB1,5-6,5M25-N0-10M 128866 from manufacturer Pepperl+Fuchs, please contact FAMAGA.

For more than 9 years our employees supply spare parts for the upgrading and maintenance of various types of technical equipment from all over the world. Over 600 orders from clients from various countries are in service daily. Developed partner network makes it possible to immediately implement order for Pepperl+Fuchs NCB1,5-6,5M25-N0-10M, while the buyer does not have to go over budget.

Geography of deliveries involves Europe, Asia, Africa and America. There is no restrictions on the size and weight of the cargo. We submit for review different delivery options so that a buyer can choose suitable balance between cost and delivery time.

Company`s fundamental rule of operation is transparency, which involves every direction of activity. Buyers get exceptionally high-quality products, to which factory warranty applies. All spare parts and equipment are original, likelihood of counterfeits are excluded. For permanent partners there are loyalty programs and they are valid affordable prices.

Become an orderer from FAMAGA, get industrial machinery with no delays and at profitable price. Fill in data in the order form on the website. Our specialist will contact you to specify details. Inquiries are also accepted by phone.

Features NCB1,5-6,5M25-N0-10M 128866

General specifications
Switching functionNormally closed (NC)
Output typeNAMUR
Rated operating distance1.5 mm
Installationflush
Assured operating distance0 ... 1.215 mm
Actual operating distance1.35 ... 1.65 mm typ.
Reduction factor rAl 0.22
Reduction factor rCu 0.19
Reduction factor r304 0.65
Output type2-wire
Nominal ratings
Nominal voltage8 V
Switching frequency0 ... 2000 Hz
Hysteresis1 ... 10 typ. 3 %
Reverse polarity protectionreverse polarity protected
Short-circuit protectionyes
Suitable for 2:1 technologyyes , Reverse polarity protection diode not required
Current consumption
Measuring plate not detectedmin. 3 mA
Measuring plate detected&le, 1 mA
Switching state indicatorLED, yellow
Functional safety related parameters
MTTFd1966 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Compliance with standards and directives
Standard conformity
NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999
StandardsEN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012
Approvals and certificates
EAC conformityTR CU 012/2011
UL approvalcULus Listed, General Purpose
CSA approvalcCSAus Listed, General Purpose
CCC approvalCCC approval / marking not required for products rated &le,36 V
Ambient conditions
Ambient temperature-25 ... 100 °C (-13 ... 212 °F)
Storage temperature-40 ... 100 °C (-40 ... 212 °F)
Mechanical specifications
Connection typecable PVC , 10 m
Core cross-section0.14 mm2
Housing materialStainless steel 1.4305 / AISI 303
Sensing faceLCP
Degree of protectionIP67
Cable
Cable diameter2.6 mm ± 0.2 mm
Bending radius> 10 x cable diameter
Equipment protection level Gb
CE marking[*PD-Z02585A*]
ATEX marking II 2G Ex ia IIC T6&hellip,T1 Gb The Ex-related marking can also be printed on the enclosed label.
StandardsEN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection Intrinsic safety Use is restricted to the following stated conditions
Appropriate typeNCB1,5...M...N0...
Effective internal capacitancemax. 90 nF , a cable length of 10 m is considered.
Effective internal inductancemax. 100 µ,H , a cable length of 10 m is considered.
Maximum permissible ambient temperatureDetails of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EC-type examination certificate.
Equipment protection level Da
CE marking[*PD-Z02585A*]
ATEX marking II 1D Ex ia IIIC T135°C Da The Ex-related marking can also be printed on the enclosed label.
StandardsEN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection Intrinsic safety Use is restricted to the following stated conditions
Appropriate typeNCB1,5...M...N0...
Effective internal capacitancemax. 90 nF , a cable length of 10 m is considered.
Effective internal inductancemax. 100 µ,H , a cable length of 10 m is considered.
Maximum permissible ambient temperature Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the surface temperature, and the effective internal reactance values can be found on the EC-type-examination certificate. The maximum permissible ambient temperature of the data sheet must be noted, in addition, the lower of the two values must be maintained.
General information
Use in the hazardous areasee instruction manuals
Category2G