Inductive sensor NBB8-18GM50-E2-3G-3D Pepperl+Fuchs 123969
Inductive sensor NBB8-18GM50-E2-3G-3D Pepperl+Fuchs 123969

We are not the manufacturer, authorised distributor or authorised representative of the Pepperl+Fuchs brand in Australia. The private labels and part numbers shown on this website are the property of their respective owners.

Pepperl+Fuchs NBB8-18GM50-E2-3G-3D 123969

Manufacturer

Pepperl+Fuchs

Country

Germany

Name

NBB8-18GM50-E2-3G-3D

Part number

123969

Type

Inductive sensor

Description

  • Increased operating distance
  • 8 mm flush
  • ATEX-approval for zone 2 and zone 22

Stock availability:

On request

Price: On request

Order

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications NBB8-18GM50-E2-3G-3D 123969

If you require NBB8-18GM50-E2-3G-3D 123969 from manufacturer Pepperl+Fuchs, please contact FAMAGA.

For more than 8 years our managers supply spare parts for the repairs and maintenance different kinds of industrial equipment from all corners of the earth. Over 750 orders from clients from various countries are arrived daily. Developed partner network makes it possible to immediately implement order for Pepperl+Fuchs NBB8-18GM50-E2-3G-3D, while the customer does not have to spend more than planned amount.

Geography of deliveries includes Europe, America, Asia and Africa. There is no restrictions on the size and mass of the cargo. We submit for review different delivery options so that a customer can choose suitable balance between cost and delivery time.

Company`s main postulate is transparency, which includes every direction of activity. Buyers get only high-quality products, to which relevant documentation from the manufacturer is available. All repair parts and equipment are original, likelihood of counterfeits are excluded. For permanent customers there are very good terms and they are valid special pricing.

Become an orderer from FAMAGA, get production with no delay and at profitable price. Fill in data in the order form on the website. Manager will contact you to discuss nuances. Orders are also accepted by phone.

Features NBB8-18GM50-E2-3G-3D 123969

General specifications
Switching functionNormally open (NO)
Output typePNP
Rated operating distance8 mm
Installationflush
Output polarityDC
Assured operating distance0 ... 6.48 mm
Reduction factor rAl 0.45
Reduction factor rCu 0.4
Reduction factor r304 0.7
Output type3-wire
Nominal ratings
Operating voltage10 ... 30 V DC
Switching frequency0 ... 500 Hz
Hysteresistyp. 5 %
Reverse polarity protectionreverse polarity protected
Short-circuit protectionpulsing
Voltage drop&le, 3 V
Operating current0 ... 200 mA
Off-state current0 ... 0.5 mA typ. 0.1 µ,A at 25 °C
No-load supply current&le, 15 mA
Time delay before availability&le, 20 ms
Switching state indicatorLED, yellow
Functional safety related parameters
MTTFd2240 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Compliance with standards and directives
Standard conformity
StandardsEN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012
Approvals and certificates
UL approvalcULus Listed, General Purpose
CSA approvalcCSAus Listed, General Purpose
CCC approvalCCC approval / marking not required for products rated &le,36 V
Ambient conditions
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Mechanical specifications
Connection typecable PVC , 2 m
Core cross-section0.34 mm2
Housing materialbrass, nickel-plated
Sensing facePBT
Degree of protectionIP66 / IP67
Cable
Cable diameter4.8 mm ± 0.2 mm
Bending radius> 10 x cable diameter
Equipment protection level Gc (nA)
CertificatePF 15CERT3754 X
CE marking[*PD-Z02586A*]
ATEX marking II 3G Ex nA IIC T6 Gc The Ex-related marking can also be printed on the enclosed label.
StandardsEN 60079-0:2012+A11:2013, EN 60079-15:2010 Ignition protection category n Use is restricted to the following stated conditions
Special conditions
Maximum operating current ILThe maximum permissible load current must be restricted to the values given in the following list. High load currents and load short-circuits are not permitted.
Maximum operating voltage UBmaxThe maximum permissible operating voltage UB max is restricted to the values in the following list. Tolerances are not permissible.
Maximum permissible ambient temperature TUmaxdependant of the load current IL and the max. operating voltage UBmax Information can be taken from the following list.
at UBmax=30 V, IL=200 mA47 °C (116.6 °F)
at UBmax=30 V, IL=100 mA52 °C (125.6 °F)
Equipment protection level Dc
CE marking[*PD-Z02586A*]
ATEX marking II 3D IP67 T 92 °C (197.6 °F) X
StandardsEN 50281-1-1 Protection via housing Use is restricted to the following stated conditions
Special conditions
Maximum heating (Temperature rise)dependant of the load current IL and the max. operating voltage UBmax Information can be taken from the following list. The maximum surface temperature at maximum ambient temperature is given in the Ex identification of the apparatus.
at UBmax=30 V, IL=200 mA22 K
at UBmax=30 V, IL=100 mA18 K
Equipment protection level Dc (tc)
CE marking[*PD-Z02586A*]
ATEX marking II 3D Ex tc IIIC T80°C Dc The Ex-related marking can also be printed on the enclosed label.
StandardsEN 60079-0:2012+A11:2013, EN 60079-31:2014 Protection by enclosure tc Some of the information in this instruction manual is more specific than the information provided in the datasheet.
GeneralThe corresponding datasheets, declarations of conformity, EC-type examination certificates, certifications, and control drawings, where applicable (see datasheets), form an integral part of this document. These documents can be found at www.pepperl-fuchs.com. The maximum surface temperature of the device was determined without a layer of dust on the apparatus. Some of the information in this instruction manual is more specific than the information provided in the datasheet.
Special conditions
Maximum permissible ambient temperature TUmaxdependant of the load current IL and the max. operating voltage UBmax Information can be taken from the following list.
at UBmax=30 V, IL=200 mA47 °C (116.6 °F)
at UBmax=30 V, IL=100 mA52 °C (125.6 °F)
General information
Use in the hazardous areasee instruction manuals
Category3G, 3D