Pepperl+Fuchs HiD2038 121484

Manufacturer

Pepperl+Fuchs

Country

Germany

Name

HiD2038

Part number

121484

Type

Current Driver

Description

SMART Current Driver HiD2038

Stock availability:

On request

Price: On request

Order

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications HiD2038 121484

This isolated barrier is used for intrinsic safety applications. It repeats a 4 mA ... 20 mA input signal from a control system to drive SMART I/P converters, valve actuators, and displays located in a hazardous area. Digital signals may be superimposed on the analog values in the hazardous or safe area, which are transferred bidirectionally. An open field circuit presents a high impedance to the control side to allow alarm conditions to be monitored by control systems. Line fault detection of the field circuit is indicated by a red LED and an output on the fault bus. The fault conditions can be monitored via a Fault Indication Board. This module mounts on a HiD Termination Board.

Features HiD2038 121484

General specifications
Signal typeAnalog output
Functional safety related parameters
Safety Integrity Level (SIL)SIL 2
Supply
ConnectionSL1: 1a(-), 1b(-), 2a(+), 2b(+)
Rated voltage20.4 ... 30 V DC bus powered via Termination Board
Rated current40 mA at 24 V, 20 mA output (per channel)
Power dissipation0.85 W at 24 V (per channel)
Input
Connection sidecontrol side
ConnectionSL1: 8a(+), 7a(-), 10a(+), 9a(-)
Input current4 ... 20 mA , reverse polarity protected
Signal levelinput voltage drop < 4 V with field wiring intact input current < 1.2 mA with field wiring open
Output
Connection sidefield side
ConnectionSL2: 5a(+), 5b(-), 1a(+), 1b(-)
Load0 ... 750 &Omega,
Output signal4 ... 20 mA
Ripple15 mV eff
Response time50 ms , 10 ... 90 % step change
Line fault detectionbreakage, load > 100 k&Omega,, short-circuit, load < 70 &Omega,
Fault indication output
ConnectionSL1: 6b
Output typeopen collector transistor (internal fault bus)
Transfer characteristics
Accuracy< ± 0.1 % of full-scale value
Influence of temperature< ± 0.01 %/K
Frequency range0.5 ... 40 kHz within 3 db, (-6 db at 100 kHz) for use with SMART positioners using HART protocol
Influence of load< ± 0.1 % of full-scale value from 0 ... 750 &Omega,
Linearity< ± 0.1 % of full-scale value
Galvanic isolation
Input/inputfunctional insulation acc. to DIN EN 50178, rated insulation voltage 50 Veff
Indicators/settings
Display elementsLEDs
Labelingspace for labeling at the front
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013 (industrial locations)
Conformity
Electromagnetic compatibilityNE 21:2006 For further information see system description.
Degree of protectionIEC 60529
Ambient conditions
Ambient temperature-20 ... 60 °C (-4 ... 140 °F)
Mechanical specifications
Degree of protectionIP20
Massapprox. 140 g
Dimensions18 x 106 x 128 mm (0.7 x 4.2 x 5 inch)
Mountingon Termination Board
Data for application in connection with hazardous areas
EU-Type Examination CertificateCESI 02 ATEX 086
Marking II (1)G [Ex ia Ga] IIC , II (1)D [Ex ia Da] IIIC
CertificatePF 11 CERT 2109 X
Marking II 3G Ex nA IIC T4 Gc [device in zone 2]
Directive conformity
Directive 2014/34/EUEN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010
International approvals
CSA approval
Control drawing366-005CS-12B (cCSAus)
IECEx approvalIECEx TUN 04.0012
Approved for[Ex ia] IIC