Name
NJ30+U1+N
Part number
106685
Type
Inductive sensor
Description
Inductive sensor NJ30+U1+N
Stock availability:
On request
If you require NJ30+U1+N 106685 from manufacturer Pepperl+Fuchs, please contact FAMAGA.
For more than 8 years our specialists supply spare parts for the renovation and maintenance of various types of manufacturing equipment from all over the world. Over 800 orders from clients from various countries are in progress daily. Developed partner network provides an opportunity to execute without delay order for Pepperl+Fuchs NJ30+U1+N, while the customer does not have to go over budget.
Geography of deliveries includes Europe, Africa, America and Asia. Australia, India, Indonesia, United States, Iran, Zambia, Central African Republic, Slovenia, Romania, Armenia, Finland, Antigua and Barbuda, Malaysia, Djibouti, Chile, Czech Republic, Latvia, Haiti, South Sudan, Kyrgyzstan, Croatia, The Gambia, San Marino, Poland, Malta, United Arab Emirates, Grenada, Gambia, Gabon, Ireland, Namibia, Colombia, Mali, Hungary, Saudi Arabia, Morocco, Albania, Syria, Argentina, South Korea, Kiribati, Iceland, Costa Rica, Eswatini, Lesotho, Palestine, France, Senegal, Luxembourg, Vietnam, Malawi, United Kingdom, Oman, Sri Lanka, Honduras, Mauritania, El Salvador, Ghana, Iraq, Philippines, Nicaragua, Bahrain, Nepal, Madagascar, Mauritius, Togo, Denmark There is no restrictions on the size and mass of the cargo. We offer different delivery options so that a customer can choose optimal compromise between cost and delivery time.
Company`s main postulate is transparency, which involves every sphere of activity. Clients get exceptionally high-quality products, to which all necessary certificates are available. All repair parts and equipment are original, risk of presence of counterfeits are excluded. For permanent partners there are exclusive offers and they are valid affordable prices.
Become an orderer from FAMAGA, get production fast and at profitable price. Fill in data in the order form on the website. Our employee will contact you to specify details. Requests are also accepted by phone.
General specifications | ||
---|---|---|
Switching function | Normally closed (NC) | |
Output type | NAMUR | |
Rated operating distance | 30 mm | |
Installation | non-flush | |
Assured operating distance | 0 ... 24.3 mm | |
Reduction factor rAl | 0.4 | |
Reduction factor rCu | 0.3 | |
Reduction factor r304 | 0.85 | |
Output type | 2-wire | |
Nominal ratings | ||
Nominal voltage | 8 V | |
Switching frequency | 0 ... 150 Hz | |
Current consumption | ||
Measuring plate not detected | min. 3 mA | |
Measuring plate detected | &le, 1 mA | |
Functional safety related parameters | ||
MTTFd | 3630 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Compliance with standards and directives | ||
Standard conformity | ||
NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
Standards | EN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 | |
Approvals and certificates | ||
FM approval | ||
Control drawing | 116-0165 | |
UL approval | ||
Ordinary Location | E87056 | |
Hazardous Location | E501628 | |
Control drawing | 116-0451 | |
CSA approval | cCSAus Listed, General Purpose | |
CCC approval | CCC approval / marking not required for products rated &le,36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) | |
Mechanical specifications | ||
Connection type | screw terminals | |
Information for connection | A maximum of two conductors with the same core cross section may be mounted on one terminal connection! tightening torque 1.2 Nm + 10 % | |
Core cross-section | up to 2.5 mm2 | |
Minimum core cross-section | without wire end ferrule 0.5 mm2 , with connector sleeves 0.34 mm2 | |
Maximum core cross-section | without wire end ferrule 2.5 mm2 , with connector sleeves 1.5 mm2 | |
Housing material | PBT | |
Sensing face | PBT | |
Degree of protection | IP68 | |
Note | Tightening torque: 1.8 Nm (housing) | |
Equipment protection level Ga | ||
CE marking | [*PD-Z02585A*] | |
ATEX marking | II 1G Ex ia IIC T6&hellip,T1 Ga The Ex-related marking can also be printed on the enclosed label. | |
Standards | EN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection Intrinsic safety Use is restricted to the following stated conditions | |
Appropriate type | NJ 30+U.+N... | |
Effective internal capacitance | max. 160 nF , a cable length of 10 m is considered. | |
Effective internal inductance | max. 130 µ,H , a cable length of 10 m is considered. | |
Ambient temperature | Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EC-type examination certificate. Note: Use the temperature table for category 1 !!! The 20 % reduction in accordance with EN 1127-1 has already been applied to the temperature table for category 1. | |
Equipment protection level Gb | ||
CE marking | [*PD-Z02585A*] | |
ATEX marking | II 1G Ex ia IIC T6&hellip,T1 Ga The Ex-related marking can also be printed on the enclosed label. | |
Standards | EN 60079-0:2012+A11:2013, EN 60079-11:2012 Ignition protection Intrinsic safety Use is restricted to the following stated conditions | |
Appropriate type | NJ 30+U.+N... | |
Effective internal capacitance | max. 160 nF , a cable length of 10 m is considered. | |
Effective internal inductance | max. 130 µ,H , a cable length of 10 m is considered. | |
Maximum permissible ambient temperature | Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EC-type examination certificate. | |
Equipment protection level Da | ||
CE marking | [*PD-Z02585A*] | |
ATEX marking | II 1D Ex ia IIIC T135°C Da The Ex-related marking can also be printed on the enclosed label. | |
Standards | EN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection Intrinsic safety Use is restricted to the following stated conditions | |
Appropriate type | NJ 30+U.+N... | |
Effective internal capacitance | max. 160 nF , a cable length of 10 m is considered. | |
Effective internal inductance | max. 130 µ,H , a cable length of 10 m is considered. | |
General information | ||
Use in the hazardous area | see instruction manuals | |
Category | 1G, 2G, 1D |