We are not the manufacturer, authorised distributor or authorised representative of the Pepperl+Fuchs brand in Australia. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Pepperl+Fuchs
Country
Germany
Name
NJ1,5-8GM-N
Part number
106361
Type
Inductive sensor
Description
Stock availability:
On request
If you require NJ1,5-8GM-N 106361 from manufacturer Pepperl+Fuchs, please contact FAMAGA.
For more than 8 years our employees supply spare parts for the renovation and maintenance of various types of manufacturing equipment from all corners of the earth. Over 800 orders from clients from various countries are arrived daily. Developed partner network provides an opportunity to execute without delay order for Pepperl+Fuchs NJ1,5-8GM-N, while the client does not have to worry about extra costs.
Geography of deliveries includes Europe, America, Africa and Asia. Australia, India, Indonesia, United States, Laos, Burma, Mozambique, Estonia, Paraguay, Monaco, Oman, Malta, Canada, Croatia, The Gambia, Saudi Arabia, Latvia, Mauritania, Slovenia, Nepal, Burkina Faso, Tanzania, Albania, Pakistan, Vietnam, Burundi, Zimbabwe, Bosnia and Herzegovina, United Kingdom, Liberia, Kazakhstan, El Salvador, Slovakia, Angola, Seychelles, Chile, Kiribati, Liechtenstein, Côte d\'Ivoire, Madagascar, Malawi, Macedonia, Afghanistan, Philippines, Papua New Guinea, Ecuador, Ethiopia, Mauritius, Serbia, Poland, Bhutan, Armenia, Dominica, Senegal, Turkey, Sri Lanka, Barbados There is no restrictions on the size and mass of the cargo. We developed different delivery options so that a buyer can choose suitable balance between cost and delivery time.
Company`s main postulate is transparency, which involves every segment of activity. Buyers get exceptionally high-quality products, to which all necessary certificates are available. All repair parts and equipment are original, risk of presence of counterfeits are excluded. For permanent buyers there are very good terms and they are valid affordable prices.
Become an orderer from FAMAGA, get production with no delay and at profitable price. Fill in data in the order form on the website. Our employee will contact you to discuss nuances. Orders are also accepted by phone.
General specifications | ||
---|---|---|
Switching function | Normally closed (NC) | |
Output type | NAMUR | |
Rated operating distance | 1.5 mm | |
Installation | flush | |
Assured operating distance | 0 ... 1.215 mm | |
Actual operating distance | 1.35 ... 1.65 mm typ. | |
Reduction factor rAl | 0.4 | |
Reduction factor rCu | 0.3 | |
Reduction factor r304 | 0.85 | |
Output type | 2-wire | |
Nominal ratings | ||
Nominal voltage | 8.2 V (Ri approx. 1 k&Omega,) | |
Switching frequency | 0 ... 5000 Hz | |
Hysteresis | 1 ... 10 typ. 5 % | |
Suitable for 2:1 technology | yes , Reverse polarity protection diode not required | |
Current consumption | ||
Measuring plate not detected | min. 3 mA | |
Measuring plate detected | &le, 1 mA | |
Functional safety related parameters | ||
Safety Integrity Level (SIL) | SIL 2 | |
Compliance with standards and directives | ||
Standard conformity | ||
NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
Standards | EN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 | |
Approvals and certificates | ||
EAC conformity | TR CU 012/2011 | |
FM approval | ||
Control drawing | 116-0165 | |
UL approval | ||
Ordinary Location | E87056 | |
Hazardous Location | E501628 | |
Control drawing | 116-0452 | |
CSA approval | cCSAus Listed, General Purpose | |
CCC approval | CCC approval / marking not required for products rated &le,36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) | |
Mechanical specifications | ||
Connection type | cable PVC , 2 m | |
Core cross-section | 0.14 mm2 | |
Housing material | Stainless steel 1.4305 / AISI 303 | |
Sensing face | PBT | |
Degree of protection | IP66 / IP67 | |
Cable | ||
Cable diameter | 2.6 mm ± 0.2 mm | |
Bending radius | > 10 x cable diameter | |
Data for application in connection with hazardous areas | ||
Equipment protection level | Ga , Gb , Da , Mb | |
Equipment protection level Ga | ||
Type of protection | intrinsic safety | |
CE marking | [*PD-Z02585A*] | |
Certificates | ||
Appropriate type | NJ1,5-8GM-N... | |
ATEX certificate | PTB 00 ATEX 2048 X | |
ATEX marking | II 1G Ex ia IIC T6...T1 Ga | |
Standards | EN 60079-0:2012 +A11:2013, EN 60079-11:2012 | |
IECEx certificate | IECEx PTB 11.0037X | |
IECEx marking | Ex ia IIC T6...T1 Ga | |
Standards | IEC 60079-0:2011 , IEC 60079-11:2011 | |
Effective internal capacitance | max. 30 nF A cable length of 10 m is considered. | |
Effective internal inductance | max. 50 µ,H A cable length of 10 m is considered. | |
Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. | |
for ATEX | at Ui = 16 V , Ii = 25 mA , Pi = 34 mW , T6 : 56 °C (132.8 °F) T5 : 68 °C (154.4 °F) T4 : 96 °C (204.8 °F) T3 : 96 °C (204.8 °F) T2 : 96 °C (204.8 °F) T1 : 96 °C (204.8 °F) at Ui = 16 V , Ii = 25 mA , Pi = 64 mW , T6 : 51 °C (123.8 °F) T5 : 63 °C (145.4 °F) T4 : 91 °C (195.8 °F) T3 : 91 °C (195.8 °F) T2 : 91 °C (195.8 °F) T1 : 91 °C (195.8 °F) at Ui = 16 V , Ii = 52 mA , Pi = 169 mW , T6 : 32 °C (89.6 °F) T5 : 44 °C (111.2 °F) T4 : 67 °C (152.6 °F) T3 : 67 °C (152.6 °F) T2 : 67 °C (152.6 °F) T1 : 67 °C (152.6 °F) at Ui = 16 V , Ii = 76 mA , Pi = 242 mW , T6 : 19 °C (66.2 °F) T5 : 31 °C (87.8 °F) T4 : 41 °C (105.8 °F) T3 : 41 °C (105.8 °F) T2 : 41 °C (105.8 °F) T1 : 41 °C (105.8 °F) | |
for IECEx | at Ui = 16 V , Ii = 25 mA , Pi = 34 mW , T6 : 73 °C (163.4 °F) T5 : 88 °C (190.4 °F) T4 : 100 °C (212 °F) T3 : 100 °C (212 °F) T2 : 100 °C (212 °F) T1 : 100 °C (212 °F) at Ui = 16 V , Ii = 25 mA , Pi = 64 mW , T6 : 68 °C (154.4 °F) T5 : 83 °C (181.4 °F) T4 : 100 °C (212 °F) T3 : 100 °C (212 °F) T2 : 100 °C (212 °F) T1 : 100 °C (212 °F) at Ui = 16 V , Ii = 52 mA , Pi = 169 mW , T6 : 49 °C (120.2 °F) T5 : 64 °C (147.2 °F) T4 : 67 °C (152.6 °F) T3 : 67 °C (152.6 °F) T2 : 67 °C (152.6 °F) T1 : 67 °C (152.6 °F) at Ui = 16 V , Ii = 76 mA , Pi = 242 mW , T6 : 36 °C (96.8 °F) T5 : 42 °C (107.6 °F) T4 : 42 °C (107.6 °F) T3 : 42 °C (107.6 °F) T2 : 42 °C (107.6 °F) T1 : 42 °C (107.6 °F) | |
Equipment protection level Gb | ||
Type of protection | intrinsic safety | |
CE marking | [*PD-Z02585A*] | |
Certificates | ||
Appropriate type | NJ1,5-8GM-N... | |
ATEX certificate | PTB 00 ATEX 2048 X | |
ATEX marking | II 1G Ex ia IIC T6&hellip,T1 Ga | |
Standards | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 | |
IECEx certificate | IECEx PTB 11.0037X | |
IECEx marking | Ex ia IIC T6...T1 Ga | |
Standards | IEC 60079-0:2011 , IEC 60079-11:2011 | |
Effective internal capacitance | max. 30 nF A cable length of 10 m is considered. | |
Effective internal inductance | max. 50 µ,H A cable length of 10 m is considered. | |
Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at Ui = 16 V , Ii = 25 mA , Pi = 34 mW , T6 : 73 °C (163.4 °F) T5 : 88 °C (190.4 °F) T4 : 100 °C (212 °F) T3 : 100 °C (212 °F) T2 : 100 °C (212 °F) T1 : 100 °C (212 °F) at Ui = 16 V , Ii = 25 mA , Pi = 64 mW , T6 : 68 °C (154.4 °F) T5 : 83 °C (181.4 °F) T4 : 100 °C (212 °F) T3 : 100 °C (212 °F) T2 : 100 °C (212 °F) T1 : 100 °C (212 °F) at Ui = 16 V , Ii = 52 mA , Pi = 169 mW , T6 : 49 °C (120.2 °F) T5 : 64 °C (147.2 °F) T4 : 67 °C (152.6 °F) T3 : 67 °C (152.6 °F) T2 : 67 °C (152.6 °F) T1 : 67 °C (152.6 °F) at Ui = 16 V , Ii = 76 mA , Pi = 242 mW , T6 : 36 °C (96.8 °F) T5 : 42 °C (107.6 °F) T4 : 42 °C (107.6 °F) T3 : 42 °C (107.6 °F) T2 : 42 °C (107.6 °F) T1 : 42 °C (107.6 °F) | |
Equipment protection level Da | ||
Type of protection | intrinsic safety | |
CE marking | [*PD-Z02585A*] | |
Certificates | ||
Appropriate type | NJ1,5-8GM-N... | |
ATEX certificate | PTB 00 ATEX 2048 X | |
ATEX marking | II 1D Ex ia IIIC T135°C Da | |
Standards | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 | |
IECEx certificate | IECEx PTB 11.0037X | |
IECEx marking | Ex ia IIIC T135°C Da | |
Standards | IEC 60079-0:2011 , IEC 60079-11:2011 | |
Effective internal capacitance | max. 30 µ,F A cable length of 10 m is considered. | |
Effective internal inductance | max. 50 µ,H A cable length of 10 m is considered. | |
Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at Ui = 16 V , Ii = 25 mA , Pi = 34 mW : 100 °C (212 °F) at Ui = 16 V , Ii = 25 mA , Pi = 64 mW : 100 °C (212 °F) at Ui = 16 V , Ii = 52 mA , Pi = 169 mW : 67 °C (152.6 °F) at Ui = 16 V , Ii = 76 mA , Pi = 242 mW : 41 °C (105.8 °F) | |
Equipment protection level Mb | ||
Type of protection | intrinsic safety | |
Certificates | ||
Appropriate type | NJ1,5-8GM-N... | |
IECEx certificate | IECEx PTB 11.0037X | |
IECEx marking | Ex ia I Mb | |
Standards | IEC 60079-0:2011 , IEC 60079-11:2011 | |
Effective internal capacitance | max. 30 nF A cable length of 10 m is considered. | |
Effective internal inductance | max. 50 µ,H A cable length of 10 m is considered. | |
Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at Ui = 16 V , Ii = 25 mA , Pi = 34 mW : 100 °C (212 °F) at Ui = 16 V , Ii = 25 mA , Pi = 64 mW : 100 °C (212 °F) at Ui = 16 V , Ii = 52 mA , Pi = 169 mW : 67 °C (152.6 °F) at Ui = 16 V , Ii = 76 mA , Pi = 242 mW : 41 °C (105.8 °F) | |
General information | ||
Use in the hazardous area | see instruction manuals |