Inductive sensor NJ1,5-8GM-N Pepperl+Fuchs 106361
Inductive sensor NJ1,5-8GM-N Pepperl+Fuchs 106361

We are not the manufacturer, authorised distributor or authorised representative of the Pepperl+Fuchs brand in Australia. The private labels and part numbers shown on this website are the property of their respective owners.

Pepperl+Fuchs NJ1,5-8GM-N 106361

Manufacturer

Pepperl+Fuchs

Country

Germany

Name

NJ1,5-8GM-N

Part number

106361

Type

Inductive sensor

Description

  • 1.5 mm flush
  • Usable up to SIL 2 acc. to IEC 61508

Stock availability:

On request

Price: On request

Order

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications NJ1,5-8GM-N 106361

If you require NJ1,5-8GM-N 106361 from manufacturer Pepperl+Fuchs, please contact FAMAGA.

For more than 8 years our employees supply spare parts for the renovation and maintenance of various types of manufacturing equipment from all corners of the earth. Over 800 orders from clients from various countries are arrived daily. Developed partner network provides an opportunity to execute without delay order for Pepperl+Fuchs NJ1,5-8GM-N, while the client does not have to worry about extra costs.

Geography of deliveries includes Europe, America, Africa and Asia. There is no restrictions on the size and mass of the cargo. We developed different delivery options so that a buyer can choose suitable balance between cost and delivery time.

Company`s main postulate is transparency, which involves every segment of activity. Buyers get exceptionally high-quality products, to which all necessary certificates are available. All repair parts and equipment are original, risk of presence of counterfeits are excluded. For permanent buyers there are very good terms and they are valid affordable prices.

Become an orderer from FAMAGA, get production with no delay and at profitable price. Fill in data in the order form on the website. Our employee will contact you to discuss nuances. Orders are also accepted by phone.

Features NJ1,5-8GM-N 106361

General specifications
Switching functionNormally closed (NC)
Output typeNAMUR
Rated operating distance1.5 mm
Installationflush
Assured operating distance0 ... 1.215 mm
Actual operating distance1.35 ... 1.65 mm typ.
Reduction factor rAl 0.4
Reduction factor rCu 0.3
Reduction factor r304 0.85
Output type2-wire
Nominal ratings
Nominal voltage8.2 V (Ri approx. 1 k&Omega,)
Switching frequency0 ... 5000 Hz
Hysteresis1 ... 10 typ. 5 %
Suitable for 2:1 technologyyes , Reverse polarity protection diode not required
Current consumption
Measuring plate not detectedmin. 3 mA
Measuring plate detected&le, 1 mA
Functional safety related parameters
Safety Integrity Level (SIL)SIL 2
Compliance with standards and directives
Standard conformity
NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999
StandardsEN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012
Approvals and certificates
EAC conformityTR CU 012/2011
FM approval
Control drawing116-0165
UL approval
Ordinary LocationE87056
Hazardous LocationE501628
Control drawing116-0452
CSA approvalcCSAus Listed, General Purpose
CCC approvalCCC approval / marking not required for products rated &le,36 V
Ambient conditions
Ambient temperature-25 ... 100 °C (-13 ... 212 °F)
Mechanical specifications
Connection typecable PVC , 2 m
Core cross-section0.14 mm2
Housing materialStainless steel 1.4305 / AISI 303
Sensing facePBT
Degree of protectionIP66 / IP67
Cable
Cable diameter2.6 mm ± 0.2 mm
Bending radius> 10 x cable diameter
Data for application in connection with hazardous areas
Equipment protection levelGa , Gb , Da , Mb
Equipment protection level Ga
Type of protectionintrinsic safety
CE marking[*PD-Z02585A*]
Certificates
Appropriate typeNJ1,5-8GM-N...
ATEX certificatePTB 00 ATEX 2048 X
ATEX marking II 1G Ex ia IIC T6...T1 Ga
StandardsEN 60079-0:2012 +A11:2013, EN 60079-11:2012
IECEx certificateIECEx PTB 11.0037X
IECEx markingEx ia IIC T6...T1 Ga
StandardsIEC 60079-0:2011 , IEC 60079-11:2011
Effective internal capacitancemax. 30 nF A cable length of 10 m is considered.
Effective internal inductancemax. 50 µ,H A cable length of 10 m is considered.
Maximum permissible ambient temperatureAlso observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values.
for ATEXat Ui = 16 V , Ii = 25 mA , Pi = 34 mW , T6 : 56 °C (132.8 °F) T5 : 68 °C (154.4 °F) T4 : 96 °C (204.8 °F) T3 : 96 °C (204.8 °F) T2 : 96 °C (204.8 °F) T1 : 96 °C (204.8 °F) at Ui = 16 V , Ii = 25 mA , Pi = 64 mW , T6 : 51 °C (123.8 °F) T5 : 63 °C (145.4 °F) T4 : 91 °C (195.8 °F) T3 : 91 °C (195.8 °F) T2 : 91 °C (195.8 °F) T1 : 91 °C (195.8 °F) at Ui = 16 V , Ii = 52 mA , Pi = 169 mW , T6 : 32 °C (89.6 °F) T5 : 44 °C (111.2 °F) T4 : 67 °C (152.6 °F) T3 : 67 °C (152.6 °F) T2 : 67 °C (152.6 °F) T1 : 67 °C (152.6 °F) at Ui = 16 V , Ii = 76 mA , Pi = 242 mW , T6 : 19 °C (66.2 °F) T5 : 31 °C (87.8 °F) T4 : 41 °C (105.8 °F) T3 : 41 °C (105.8 °F) T2 : 41 °C (105.8 °F) T1 : 41 °C (105.8 °F)
for IECExat Ui = 16 V , Ii = 25 mA , Pi = 34 mW , T6 : 73 °C (163.4 °F) T5 : 88 °C (190.4 °F) T4 : 100 °C (212 °F) T3 : 100 °C (212 °F) T2 : 100 °C (212 °F) T1 : 100 °C (212 °F) at Ui = 16 V , Ii = 25 mA , Pi = 64 mW , T6 : 68 °C (154.4 °F) T5 : 83 °C (181.4 °F) T4 : 100 °C (212 °F) T3 : 100 °C (212 °F) T2 : 100 °C (212 °F) T1 : 100 °C (212 °F) at Ui = 16 V , Ii = 52 mA , Pi = 169 mW , T6 : 49 °C (120.2 °F) T5 : 64 °C (147.2 °F) T4 : 67 °C (152.6 °F) T3 : 67 °C (152.6 °F) T2 : 67 °C (152.6 °F) T1 : 67 °C (152.6 °F) at Ui = 16 V , Ii = 76 mA , Pi = 242 mW , T6 : 36 °C (96.8 °F) T5 : 42 °C (107.6 °F) T4 : 42 °C (107.6 °F) T3 : 42 °C (107.6 °F) T2 : 42 °C (107.6 °F) T1 : 42 °C (107.6 °F)
Equipment protection level Gb
Type of protectionintrinsic safety
CE marking[*PD-Z02585A*]
Certificates
Appropriate typeNJ1,5-8GM-N...
ATEX certificatePTB 00 ATEX 2048 X
ATEX marking II 1G Ex ia IIC T6&hellip,T1 Ga
StandardsEN 60079-0:2012+A11:2013 , EN 60079-11:2012
IECEx certificateIECEx PTB 11.0037X
IECEx markingEx ia IIC T6...T1 Ga
StandardsIEC 60079-0:2011 , IEC 60079-11:2011
Effective internal capacitancemax. 30 nF A cable length of 10 m is considered.
Effective internal inductancemax. 50 µ,H A cable length of 10 m is considered.
Maximum permissible ambient temperatureAlso observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at Ui = 16 V , Ii = 25 mA , Pi = 34 mW , T6 : 73 °C (163.4 °F) T5 : 88 °C (190.4 °F) T4 : 100 °C (212 °F) T3 : 100 °C (212 °F) T2 : 100 °C (212 °F) T1 : 100 °C (212 °F) at Ui = 16 V , Ii = 25 mA , Pi = 64 mW , T6 : 68 °C (154.4 °F) T5 : 83 °C (181.4 °F) T4 : 100 °C (212 °F) T3 : 100 °C (212 °F) T2 : 100 °C (212 °F) T1 : 100 °C (212 °F) at Ui = 16 V , Ii = 52 mA , Pi = 169 mW , T6 : 49 °C (120.2 °F) T5 : 64 °C (147.2 °F) T4 : 67 °C (152.6 °F) T3 : 67 °C (152.6 °F) T2 : 67 °C (152.6 °F) T1 : 67 °C (152.6 °F) at Ui = 16 V , Ii = 76 mA , Pi = 242 mW , T6 : 36 °C (96.8 °F) T5 : 42 °C (107.6 °F) T4 : 42 °C (107.6 °F) T3 : 42 °C (107.6 °F) T2 : 42 °C (107.6 °F) T1 : 42 °C (107.6 °F)
Equipment protection level Da
Type of protectionintrinsic safety
CE marking[*PD-Z02585A*]
Certificates
Appropriate typeNJ1,5-8GM-N...
ATEX certificatePTB 00 ATEX 2048 X
ATEX marking II 1D Ex ia IIIC T135°C Da
StandardsEN 60079-0:2012+A11:2013 , EN 60079-11:2012
IECEx certificateIECEx PTB 11.0037X
IECEx markingEx ia IIIC T135°C Da
StandardsIEC 60079-0:2011 , IEC 60079-11:2011
Effective internal capacitancemax. 30 µ,F A cable length of 10 m is considered.
Effective internal inductancemax. 50 µ,H A cable length of 10 m is considered.
Maximum permissible ambient temperatureAlso observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at Ui = 16 V , Ii = 25 mA , Pi = 34 mW : 100 °C (212 °F) at Ui = 16 V , Ii = 25 mA , Pi = 64 mW : 100 °C (212 °F) at Ui = 16 V , Ii = 52 mA , Pi = 169 mW : 67 °C (152.6 °F) at Ui = 16 V , Ii = 76 mA , Pi = 242 mW : 41 °C (105.8 °F)
Equipment protection level Mb
Type of protectionintrinsic safety
Certificates
Appropriate typeNJ1,5-8GM-N...
IECEx certificateIECEx PTB 11.0037X
IECEx markingEx ia I Mb
StandardsIEC 60079-0:2011 , IEC 60079-11:2011
Effective internal capacitancemax. 30 nF A cable length of 10 m is considered.
Effective internal inductancemax. 50 µ,H A cable length of 10 m is considered.
Maximum permissible ambient temperatureAlso observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at Ui = 16 V , Ii = 25 mA , Pi = 34 mW : 100 °C (212 °F) at Ui = 16 V , Ii = 25 mA , Pi = 64 mW : 100 °C (212 °F) at Ui = 16 V , Ii = 52 mA , Pi = 169 mW : 67 °C (152.6 °F) at Ui = 16 V , Ii = 76 mA , Pi = 242 mW : 41 °C (105.8 °F)
General information
Use in the hazardous areasee instruction manuals