We are not the manufacturer, authorised distributor or authorised representative of the Pepperl+Fuchs brand in Australia. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Pepperl+Fuchs
Country
Germany
Part number
310839
Type
Inductive sensor
Description
Inductive sensor NCN4-12GM40-E2-V1-3G-3D
Stock availability:
On request
If you require 310839 from manufacturer Pepperl+Fuchs, please contact FAMAGA.
For more than 9 years our employees supply repair parts for the renovation and maintenance different kinds of manufacturing equipment from all corners of the earth. Over 800 orders from clients from different countries are in service daily. Developed partner network provides an opportunity to execute without delay order for Pepperl+Fuchs , while the client does not have to spend more than planned amount.
Geography of deliveries includes Europe, America, Africa and Asia. Australia, India, Indonesia, United States, Kazakhstan, Costa Rica, Guyana, Cape Verde, Congo, Philippines, Belize, Finland, Luxembourg, Saudi Arabia, El Salvador, San Marino, Zimbabwe, Malta, Slovenia, Montenegro, Angola, Brunei, Croatia, Bahamas, Iraq, Liechtenstein, France, Chile, South Sudan, Serbia, Namibia, Ghana, United Kingdom, Switzerland, Togo, Swaziland, Peru, South Korea, Germany, Senegal, Lebanon, Liberia, Lithuania, The Gambia, Armenia, Panama, Argentina, Equatorial Guinea, Oman, Kiribati, Mauritius, Mauritania, Cambodia, Guinea-Bissau, Comoros, Ethiopia, Lesotho, Vietnam, Papua New Guinea There is no restrictions on the size and mass of the cargo. We developed different delivery options so that a client can choose optimal compromise between cost and delivery time.
Company`s main principle of operation is transparency, which involves every segment of activity. Customers get exceptionally high-quality products, to which factory warranty applies. All repair parts and equipment are original, risk of presence of counterfeits are excluded. For permanent customers there are loyalty programs and they are valid special pricing.
Become a customer from FAMAGA, get production with no delays and at profitable price. Fill in the order form on the website. Our employee will contact you to discuss nuances. Inquiries are also accepted by phone.
General specifications | ||
---|---|---|
Switching function | Normally open (NO) | |
Output type | PNP | |
Rated operating distance | 4 mm | |
Installation | non-flush | |
Output polarity | DC | |
Assured operating distance | 0 ... 3.24 mm | |
Actual operating distance | 3.6 ... 4.4 mm typ. 4 mm | |
Reduction factor rAl | 0.4 | |
Reduction factor rCu | 0.36 | |
Reduction factor r304 | 0.74 | |
Reduction factor rBrass | 0.45 | |
Output type | 3-wire | |
Nominal ratings | ||
Operating voltage | 10 ... 30 V DC | |
Switching frequency | 0 ... 2200 Hz | |
Hysteresis | 3 ... 15 typ. 7 % | |
Reverse polarity protection | reverse polarity protected | |
Short-circuit protection | pulsing | |
Voltage drop | &le, 3 V | |
Voltage drop at IL | ||
Voltage drop IL = 200 mA, switching element on | 1 ... 2 V typ. 1.5 V | |
Operating current | &le, 200 mA | |
Off-state current | 0 ... 0.5 mA typ. 0.01 mA | |
No-load supply current | &le, 15 mA | |
Time delay before availability | &le, 100 ms | |
Switching state indicator | LED, yellow | |
Functional safety related parameters | ||
MTTFd | 1517 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Compliance with standards and directives | ||
Standard conformity | ||
Standards | EN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
CCC approval | CCC approval / marking not required for products rated &le,36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Mechanical specifications | ||
Connection type | Connector plug M12 x 1 , 4-pin | |
Housing material | Stainless steel 1.4305 / AISI 303 | |
Sensing face | PBT | |
Degree of protection | IP66 / IP67 | |
Data for application in connection with hazardous areas | ||
Equipment protection level | Gc (nA) , Dc | |
Equipment protection level Gc (nA) | ||
Type of protection | n | |
CE marking | [*PD-Z02586A*] | |
Certificates | ||
ATEX certificate | PF15CERT3754X | |
ATEX marking | II 3G Ex nA IIC T6 Gc | |
Standards | EN 60079-0:2012+A11:2013 , EN 60079-15:2010 | |
Surge protection | The protection against transient overvoltage with amplitude U is realized. U = 500 V at 1.2/50 µ,s, 500 &Omega, | |
Possible characteristics | maximum operating voltage UBmax , maximum load current ILmax , minimum series resistance RV , maximum analog output voltage UAmax , maximum analog output current IAmax | |
Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at UBmax = 30 V , IL = 200 mA : 43 °C (109.4 °F) at UBmax = 30 V , IL = 100 mA : 50 °C (122 °F) at UBmax = 30 V , IL = 50 mA : 53 °C (127.4 °F) | |
Equipment protection level Dc | ||
Type of protection | Protection by enclosure tc | |
CE marking | [*PD-Z02586A*] | |
Certificates | ||
ATEX certificate | PF15CERT3774X | |
ATEX marking | II 3D Ex tc IIIC T80°C Dc | |
Standards | EN 60079-0:2012+A11:2013 , EN 60079-31:2014 | |
Possible characteristics | maximum operating voltage UBmax , maximum load current ILmax , minimum series resistance RV , maximum analog output current IAmax , maximum analog output voltage UAmax | |
Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at UBmax = 30 V , IL = 200 mA : 43 °C (109.4 °F) at UBmax = 30 V , IL = 100 mA : 50 °C (122 °F) at UBmax = 30 V , IL = 50 mA : 53 °C (127.4 °F) | |
General information | ||
Scope of delivery | 2 self locking nuts in scope of delivery | |
Use in the hazardous area | see instruction manuals |