Inductive sensor NCN4-12GM40-E2-3G-3D Pepperl+Fuchs 310841
Inductive sensor NCN4-12GM40-E2-3G-3D Pepperl+Fuchs 310841

We are not the manufacturer, authorised distributor or authorised representative of the Pepperl+Fuchs brand in Australia. The private labels and part numbers shown on this website are the property of their respective owners.

Pepperl+Fuchs NCN4-12GM40-E2-3G-3D 310841

Manufacturer

Pepperl+Fuchs

Country

Germany

Name

NCN4-12GM40-E2-3G-3D

Part number

310841

Type

Inductive sensor

Description

Inductive sensor NCN4-12GM40-E2-3G-3D

Stock availability:

On request

Price: On request

Order

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications NCN4-12GM40-E2-3G-3D 310841

If you require NCN4-12GM40-E2-3G-3D 310841 from manufacturer Pepperl+Fuchs, please contact FAMAGA.

For more than 10 years our managers supply spare parts for the upgrading and maintenance different kinds of industrial equipment from all parts of the planet. Over 700 orders from clients from various countries are arrived daily. Developed partner network allows you to quickly execute order for Pepperl+Fuchs NCN4-12GM40-E2-3G-3D, while the buyer does not have to worry about extra costs.

Geography of deliveries involves Europe, Asia, Africa and America. There is no restrictions on the size and mass of the cargo. We submit for review different delivery options so that a buyer can choose optimal compromise between cost and delivery time.

Company`s main postulate is transparency, which covers every direction of activity. Buyers get top-class spare parts and equipment, to which all necessary certificates are available. All repair parts and equipment are original, risk of presence of counterfeits are excluded. For permanent partners there are loyalty programs and they are valid affordable prices.

Become a customer from FAMAGA, get equipment with no delay and at beneficial price. Fill in data in the order form on the website. Manager will contact you to discuss details. Orders are also accepted by phone.

Features NCN4-12GM40-E2-3G-3D 310841

General specifications
Switching functionNormally open (NO)
Output typePNP
Rated operating distance4 mm
Installationnon-flush
Output polarityDC
Assured operating distance0 ... 3.24 mm
Actual operating distance3.6 ... 4.4 mm typ. 4 mm
Reduction factor rAl 0.4
Reduction factor rCu 0.36
Reduction factor r304 0.74
Reduction factor rBrass 0.45
Output type3-wire
Nominal ratings
Operating voltage10 ... 30 V DC
Switching frequency0 ... 2200 Hz
Hysteresis3 ... 15 typ. 7 %
Reverse polarity protectionreverse polarity protected
Short-circuit protectionpulsing
Voltage drop&le, 3 V
Voltage drop at IL
Voltage drop IL = 200 mA, switching element on1 ... 2 V typ. 1.5 V
Operating current&le, 200 mA
Off-state current0 ... 0.5 mA typ. 0.01 mA
No-load supply current&le, 15 mA
Time delay before availability&le, 100 ms
Switching state indicatorLED, yellow
Functional safety related parameters
MTTFd1517 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Compliance with standards and directives
Standard conformity
StandardsEN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012
Approvals and certificates
UL approvalcULus Listed, General Purpose, Class 2 Power Source
CCC approvalCCC approval / marking not required for products rated &le,36 V
Ambient conditions
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Mechanical specifications
Connection typecable PVC , 2 m
Core cross-section0.34 mm2
Housing materialStainless steel 1.4305 / AISI 303
Sensing facePBT
Degree of protectionIP66 / IP67
Cable
Cable diameter4.6 mm ± 0.2 mm
Bending radius> 10 x cable diameter
Data for application in connection with hazardous areas
Equipment protection levelGc (nA) , Dc
Equipment protection level Gc (nA)
Type of protectionn
CE marking[*PD-Z02586A*]
Certificates
ATEX certificatePF15CERT3754X
ATEX marking II 3G Ex nA IIC T6 Gc
StandardsEN 60079-0:2012+A11:2013 , EN 60079-15:2010
Surge protectionThe protection against transient overvoltage with amplitude U is realized. U = 500 V at 1.2/50 µ,s, 500 &Omega,
Possible characteristicsmaximum operating voltage UBmax , maximum load current ILmax , minimum series resistance RV , maximum analog output voltage UAmax , maximum analog output current IAmax
Maximum permissible ambient temperatureAlso observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at UBmax = 30 V , IL = 200 mA : 43 °C (109.4 °F) at UBmax = 30 V , IL = 100 mA : 50 °C (122 °F) at UBmax = 30 V , IL = 50 mA : 53 °C (127.4 °F)
Equipment protection level Dc
Type of protectionProtection by enclosure tc
CE marking[*PD-Z02586A*]
Certificates
ATEX certificatePF15CERT3774X
ATEX marking II 3D Ex tc IIIC T80°C Dc
StandardsEN 60079-0:2012+A11:2013 , EN 60079-31:2014
Possible characteristicsmaximum operating voltage UBmax , maximum load current ILmax , minimum series resistance RV , maximum analog output current IAmax , maximum analog output voltage UAmax
Maximum permissible ambient temperatureAlso observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at UBmax = 30 V , IL = 200 mA : 43 °C (109.4 °F) at UBmax = 30 V , IL = 100 mA : 50 °C (122 °F) at UBmax = 30 V , IL = 50 mA : 53 °C (127.4 °F)
General information
Scope of delivery2 self locking nuts in scope of delivery
Use in the hazardous areasee instruction manuals