We are not the manufacturer, authorised distributor or authorised representative of the Pepperl+Fuchs brand in Australia. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Pepperl+Fuchs
Country
Germany
Name
NCN3-F25F-N4-Y41364
Part number
291804
Type
Inductive sensor
Description
Inductive sensor NCN3-F25F-N4-Y41364
Stock availability:
On request
If you require NCN3-F25F-N4-Y41364 291804 from manufacturer Pepperl+Fuchs, please contact FAMAGA.
For more than 8 years our employees supply spare parts for the repairs and maintenance different kinds of industrial equipment from all corners of the earth. Over 650 orders from clients from various countries are in progress daily. Developed partner network allows you to quickly execute order for Pepperl+Fuchs NCN3-F25F-N4-Y41364, while the client does not have to go over budget.
Geography of deliveries involves Europe, Africa, America and Asia. Australia, India, Indonesia, United States, Yemen, Syria, Slovenia, France, San Marino, Ethiopia, Bhutan, Mexico, China, Chad, Vietnam, Uruguay, Cameroon, Eswatini, Central African Republic, Mongolia, Moldova, Tonga, United Kingdom, Sierra Leone, Palestine, The Gambia, Mauritania, Armenia, Angola, Fiji, South Korea, Honduras, Lithuania, United Arab Emirates, Gabon, Kyrgyzstan, Liberia, Antigua and Barbuda, Bangladesh, Guyana, Togo, Malawi, Burundi, Lesotho, Equatorial Guinea, Gambia, Canada, South Africa, Senegal, Dominica, Madagascar, Ecuador, Venezuela, Montenegro, Kiribati, Mali, Philippines, Benin There is no restrictions on the size and weight of the cargo. We developed different delivery options so that a customer can choose suitable balance between cost and delivery time.
Company`s main postulate is transparency, which covers every segment of activity. Clients get top-class spare parts and equipment, to which all necessary certificates are available. All spare parts and equipment are original, likelihood of counterfeits are excluded. For permanent partners there are bonus programs and they are valid affordable prices.
Become a buyer from FAMAGA, get components fast and at beneficial price. Fill in data in the order form on the website. Manager will contact you to discuss nuances. Requests are also accepted by phone.
General specifications | ||
---|---|---|
Switching function | 2 x normally closed (NC) | |
Output type | NAMUR | |
Rated operating distance | 3 mm | |
Installation | flush mountable | |
Assured operating distance | 0 ... 2.43 mm | |
Actual operating distance | 2.7 ... 3.3 mm typ. | |
Reduction factor rAl | 0.52 | |
Reduction factor rCu | 0.43 | |
Reduction factor r304 | 0.86 | |
Reduction factor rSt37 | 1 | |
Reduction factor rBrass | 0.54 | |
Output type | 2-wire | |
Nominal ratings | ||
Nominal voltage | 8.2 V (Ri approx. 1 k&Omega,) | |
Switching frequency | 0 ... 1500 Hz | |
Hysteresis | typ. 5 % | |
Reverse polarity protection | reverse polarity protected | |
Short-circuit protection | yes | |
Suitable for 2:1 technology | yes , Reverse polarity protection diode not required | |
Current consumption | ||
Measuring plate not detected | &ge, 3 mA | |
Measuring plate detected | &le, 1 mA | |
Time delay before availability | &le, 1 ms | |
Switching state indicator | LED, yellow | |
Functional safety related parameters | ||
MTTFd | 1038 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Compliance with standards and directives | ||
Standard conformity | ||
NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
Electromagnetic compatibility | NE 21:2007 | |
Standards | EN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 | |
Approvals and certificates | ||
FM approval | ||
Control drawing | 116-0165 | |
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
Ambient conditions | ||
Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) | |
Storage temperature | -40 ... 100 °C (-40 ... 212 °F) | |
Mechanical specifications | ||
Connection type | MINI-COMBICON | |
Housing material | PBT | |
Sensing face | PBT | |
Degree of protection | IP67 (Sensor side) IP20 (Connection side) | |
Mass | 37 g | |
Tightening torque, fastening screws | M5 x 25 : 2.7 Nm | |
Note | Please use Phönix FK-MCP 1,5/4-ST-3,81 connector | |
Data for application in connection with hazardous areas | ||
Equipment protection level | Ga , Gb , Gc (ic) , Da , Mb | |
Equipment protection level Ga | ||
Type of protection | intrinsic safety | |
CE marking | [*PD-Z02585A*] | |
Certificates | ||
Appropriate type | NCN3-F25.-N4... | |
ATEX certificate | TÜV 99 ATEX 1479 X | |
ATEX marking | II 1G Ex ia IIC T6...T1 Ga | |
Standards | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 | |
IECEx certificate | IECEx TUN 17.0021X | |
IECEx marking | Ex ia IIC T6...T1 Ga | |
Standards | IEC 60079-0:2011 , IEC 60079-11:2011 | |
Effective internal capacitance | max. 100 nF The value is applicable for one sensor circuit. A cable length of 10 m is considered. | |
Effective internal inductance | max. 100 µ,H The value is applicable for one sensor circuit. A cable length of 10 m is considered. | |
Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. | |
for ATEX | at Ui = 15 V , Ii = 25 mA , Pi = 34 mW , T6 : 55 °C (131 °F) T5 : 70 °C (158 °F) T4 : 95 °C (203 °F) T3 : 95 °C (203 °F) T2 : 95 °C (203 °F) T1 : 95 °C (203 °F) at Ui = 15 V , Ii = 25 mA , Pi = 64 mW , T6 : 55 °C (131 °F) T5 : 65 °C (149 °F) T4 : 95 °C (203 °F) T3 : 95 °C (203 °F) T2 : 95 °C (203 °F) T1 : 95 °C (203 °F) at Ui = 15 V , Ii = 52 mA , Pi = 169 mW , T6 : 45 °C (113 °F) T5 : 55 °C (131 °F) T4 : 85 °C (185 °F) T3 : 85 °C (185 °F) T2 : 85 °C (185 °F) T1 : 85 °C (185 °F) | |
for IECEx | at Ui = 15 V , Ii = 25 mA , Pi = 34 mW , T6 : 75 °C (167 °F) T5 : 90 °C (194 °F) T4 : 100 °C (212 °F) T3 : 100 °C (212 °F) T2 : 100 °C (212 °F) T1 : 100 °C (212 °F) at Ui = 15 V , Ii = 25 mA , Pi = 64 mW , T6 : 70 °C (158 °F) T5 : 85 °C (185 °F) T4 : 100 °C (212 °F) T3 : 100 °C (212 °F) T2 : 100 °C (212 °F) T1 : 100 °C (212 °F) at Ui = 15 V , Ii = 52 mA , Pi = 169 mW , T6 : 60 °C (140 °F) T5 : 75 °C (167 °F) T4 : 95 °C (203 °F) T3 : 95 °C (203 °F) T2 : 95 °C (203 °F) T1 : 95 °C (203 °F) | |
Equipment protection level Gb | ||
Type of protection | intrinsic safety | |
CE marking | [*PD-Z02585A*] | |
Certificates | ||
Appropriate type | NCN3-F25.-N4... | |
ATEX certificate | TÜV 99 ATEX 1479 X | |
ATEX marking | II 1G Ex ia IIC T6&hellip,T1 Ga | |
Standards | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 | |
IECEx certificate | IECEx TUN 17.0021X | |
IECEx marking | Ex ia IIC T6...T1 Ga | |
Standards | IEC 60079-0:2011 , IEC 60079-11:2011 | |
Effective internal capacitance | max. 100 nF The value is applicable for one sensor circuit. A cable length of 10 m is considered. | |
Effective internal inductance | max. 100 µ,H The value is applicable for one sensor circuit. A cable length of 10 m is considered. | |
Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at Ui = 15 V , Ii = 25 mA , Pi = 34 mW , T6 : 75 °C (167 °F) T5 : 90 °C (194 °F) T4 : 100 °C (212 °F) T3 : 100 °C (212 °F) T2 : 100 °C (212 °F) T1 : 100 °C (212 °F) at Ui = 15 V , Ii = 25 mA , Pi = 64 mW , T6 : 70 °C (158 °F) T5 : 85 °C (185 °F) T4 : 100 °C (212 °F) T3 : 100 °C (212 °F) T2 : 100 °C (212 °F) T1 : 100 °C (212 °F) at Ui = 15 V , Ii = 52 mA , Pi = 169 mW , T6 : 60 °C (140 °F) T5 : 75 °C (167 °F) T4 : 95 °C (203 °F) T3 : 95 °C (203 °F) T2 : 95 °C (203 °F) T1 : 95 °C (203 °F) | |
Equipment protection level Gc (ic) | ||
Type of protection | intrinsic safety | |
CE marking | [*PD-Z02585A*] | |
Certificates | ||
ATEX certificate | PF 13 CERT 2895 X | |
ATEX marking | II 3G Ex ic IIC T6&hellip,T1 Gc | |
Standards | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 | |
Effective internal capacitance | max. 100 nF The value is applicable for one sensor circuit. A cable length of 10 m is considered. | |
Effective internal inductance | max. 100 µ,H The value is applicable for one sensor circuit. A cable length of 10 m is considered. | |
Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at Ui = 20 V , Ii = 25 mA , Pi = 34 mW , T6 : 75 °C (167 °F) T5 : 90 °C (194 °F) T4 : 100 °C (212 °F) T3 : 100 °C (212 °F) T2 : 100 °C (212 °F) T1 : 100 °C (212 °F) at Ui = 20 V , Ii = 25 mA , Pi = 64 mW , T6 : 70 °C (158 °F) T5 : 85 °C (185 °F) T4 : 100 °C (212 °F) T3 : 100 °C (212 °F) T2 : 100 °C (212 °F) T1 : 100 °C (212 °F) at Ui = 20 V , Ii = 52 mA , Pi = 169 mW , T6 : 60 °C (140 °F) T5 : 75 °C (167 °F) T4 : 95 °C (203 °F) T3 : 95 °C (203 °F) T2 : 95 °C (203 °F) T1 : 95 °C (203 °F) | |
Equipment protection level Da | ||
Type of protection | intrinsic safety | |
CE marking | [*PD-Z02585A*] | |
Certificates | ||
Appropriate type | NCN3-F25.-N4... | |
ATEX certificate | TÜV 99 ATEX 1479 X | |
ATEX marking | II 1D Ex ia IIIC T135°C Da | |
Standards | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 | |
IECEx certificate | IECEx TUN 17.0021X | |
IECEx marking | Ex ia IIIC T135°C Da | |
Standards | IEC 60079-0:2011 , IEC 60079-11:2011 | |
Effective internal capacitance | max. 100 nF A cable length of 10 m is considered. | |
Effective internal inductance | max. 100 µ,H A cable length of 10 m is considered. | |
Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at Ui = 15 V , Ii = 25 mA , Pi = 34 mW : 100 °C (212 °F) at Ui = 15 V , Ii = 25 mA , Pi = 64 mW : 100 °C (212 °F) at Ui = 15 V , Ii = 52 mA , Pi = 169 mW : 95 °C (203 °F) | |
Equipment protection level Mb | ||
Type of protection | intrinsic safety | |
CE marking | [*PD-Z02585A*] | |
Certificates | ||
Appropriate type | NCN3-F25.-N4... | |
IECEx certificate | IECEx TUN 17.0021X | |
IECEx marking | Ex ia I Mb | |
Standards | IEC 60079-0:2011 , IEC 60079-11:2011 | |
Effective internal capacitance | max. 100 nF The value is applicable for one sensor circuit. A cable length of 10 m is considered. | |
Effective internal inductance | max. 100 µ,H The value is applicable for one sensor circuit. A cable length of 10 m is considered. | |
Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at Ui = 15 V , Ii = 25 mA , Pi = 34 mW : 100 °C (212 °F) at Ui = 15 V , Ii = 25 mA , Pi = 64 mW : 100 °C (212 °F) at Ui = 15 V , Ii = 52 mA , Pi = 169 mW : 95 °C (203 °F) | |
General information | ||
Use in the hazardous area | see instruction manuals |