Inductive sensor NBN40-L2-E2-V1-3G-3D Pepperl+Fuchs 317344
Inductive sensor NBN40-L2-E2-V1-3G-3D Pepperl+Fuchs 317344

We are not the manufacturer, authorised distributor or authorised representative of the Pepperl+Fuchs brand in Australia. The private labels and part numbers shown on this website are the property of their respective owners.

Pepperl+Fuchs NBN40-L2-E2-V1-3G-3D 317344

Manufacturer

Pepperl+Fuchs

Country

Germany

Name

NBN40-L2-E2-V1-3G-3D

Part number

317344

Type

Inductive sensor

Description

Inductive sensor NBN40-L2-E2-V1-3G-3D

Stock availability:

On request

Price: On request

Order

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications NBN40-L2-E2-V1-3G-3D 317344

If you require NBN40-L2-E2-V1-3G-3D 317344 from manufacturer Pepperl+Fuchs, please contact FAMAGA.

For more than 8 years our employees supply spare parts for the repairs and maintenance different kinds of manufacturing equipment from all parts of the planet. Over 700 orders from clients from various countries are in service daily. Developed partner network provides an opportunity to execute without delay order for Pepperl+Fuchs NBN40-L2-E2-V1-3G-3D, while the client does not have to worry about extra costs.

Geography of deliveries involves Europe, America, Africa and Asia. There is no restrictions on the size and mass of the cargo. We developed different delivery options so that a client can choose suitable balance between cost and delivery time.

Company`s fundamental rule of operation is transparency, which involves every direction of activity. Customers get top-class spare parts and equipment, to which all necessary certificates are available. All spare parts and equipment are original, likelihood of counterfeits are excluded. For permanent customers there are very good terms and they are valid great deals.

Become a customer from FAMAGA, get industrial machinery with no delays and at profitable price. Fill in information in the order form on the website. Our employee will contact you to discuss details. Inquiries are also accepted by phone.

Features NBN40-L2-E2-V1-3G-3D 317344

General specifications
Switching functionNormally open (NO)
Output typePNP
Rated operating distance40 mm
Installationnon-flush
Output polarityDC
Assured operating distance0 ... 32.4 mm
Actual operating distance36 ... 44 mm typ. 40 mm
Reduction factor rAl 0.33
Reduction factor rCu 0.31
Reduction factor r304 0.74
Reduction factor rBrass 0.38
Output type3-wire
Nominal ratings
Operating voltage10 ... 30 V DC
Switching frequency0 ... 180 Hz
Hysteresistyp. 5 %
Reverse polarity protectionreverse polarity protected
Short-circuit protectionpulsing
Voltage drop&le, 2 V
Operating current0 ... 200 mA
Off-state current0 ... 0.5 mA
No-load supply current&le, 20 mA
Time delay before availability80 ms
Operating voltage indicatorLED, green
Switching state indicatorLED, yellow
Functional safety related parameters
MTTFd1057 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Compliance with standards and directives
Standard conformity
StandardsEN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012
Approvals and certificates
Protection classII
Rated insulation voltage253 V
Rated impulse withstand voltage4000 V
UL approvalcULus Listed, General Purpose
CCC approvalCCC approval / marking not required for products rated &le,36 V
Ambient conditions
Ambient temperature-25 ... 85 °C (-13 ... 185 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Mechanical specifications
Connection typeConnector plug M12 x 1 , 4-pin
Housing materialPA
Sensing facePA
Degree of protectionIP69K
Cable
Cable diameter3.3 mm ± 0.15 mm
Mass130 g
Data for application in connection with hazardous areas
Equipment protection levelGc (nA) , Dc
Equipment protection level Gc (nA)
Type of protectionn
CE marking[*PD-Z02586A*]
Certificates
ATEX certificatePF15CERT3754X
ATEX marking II 3G Ex nA IIC T6 Gc
StandardsEN 60079-0:2012+A11:2013 , EN 60079-15:2010
Possible characteristicsmaximum operating voltage UBmax , maximum load current ILmax , minimum series resistance RV , maximum analog output voltage UAmax , maximum analog output current IAmax
Maximum permissible ambient temperatureAlso observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at UBmax = 30 V , IL = 200 mA : 48 °C (118.4 °F) at UBmax = 30 V , IL = 100 mA : 50 °C (122 °F) at UBmax = 30 V , IL = 50 mA : 51 °C (123.8 °F) at UBmax = 30 V , IL = 25 mA : 52 °C (125.6 °F)
Equipment protection level Dc
Type of protectionProtection by enclosure tc
CE marking[*PD-Z02586A*]
Certificates
ATEX certificatePF15CERT3774X
ATEX marking II 3D Ex tc IIIC T80°C Dc
StandardsEN 60079-0:2012+A11:2013 , EN 60079-31:2014
Maximum permissible ambient temperatureAlso observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at UBmax = 30 V , IL = 200 mA : 48 °C (118.4 °F) at UBmax = 30 V , IL = 100 mA : 50 °C (122 °F) at UBmax = 30 V , IL = 50 mA : 51 °C (123.8 °F) at UBmax = 30 V , IL = 25 mA : 52 °C (125.6 °F)
General information
Use in the hazardous areasee instruction manuals