Name
NBN40-L2-E2-V1-3G-3D
Part number
317344
Type
Inductive sensor
Description
Inductive sensor NBN40-L2-E2-V1-3G-3D
Stock availability:
On request
If you require NBN40-L2-E2-V1-3G-3D 317344 from manufacturer Pepperl+Fuchs, please contact FAMAGA.
For more than 8 years our employees supply spare parts for the repairs and maintenance different kinds of manufacturing equipment from all parts of the planet. Over 700 orders from clients from various countries are in service daily. Developed partner network provides an opportunity to execute without delay order for Pepperl+Fuchs NBN40-L2-E2-V1-3G-3D, while the client does not have to worry about extra costs.
Geography of deliveries involves Europe, America, Africa and Asia. Australia, India, Indonesia, United States, Tanzania, Eswatini, Nigeria, Tunisia, Grenada, Montenegro, Belgium, Malaysia, Libya, South Korea, Central African Republic, Belize, Yemen, Estonia, Comoros, Guinea, Zambia, Tonga, El Salvador, Suriname, Poland, Luxembourg, Turkmenistan, Mozambique, Ethiopia, Mexico, United Kingdom, Fiji, Bosnia and Herzegovina, Switzerland, Myanmar, Angola, Malta, Iceland, South Sudan, Burundi, Equatorial Guinea, Vietnam, Colombia, Argentina, Denmark, Haiti, Guyana, Antigua and Barbuda, Sri Lanka, Lebanon, Philippines, Afghanistan, Mali, Côte d\'Ivoire, Kiribati, Singapore, Senegal, Kazakhstan, Guinea-Bissau, Bahrain There is no restrictions on the size and mass of the cargo. We developed different delivery options so that a client can choose suitable balance between cost and delivery time.
Company`s fundamental rule of operation is transparency, which involves every direction of activity. Customers get top-class spare parts and equipment, to which all necessary certificates are available. All spare parts and equipment are original, likelihood of counterfeits are excluded. For permanent customers there are very good terms and they are valid great deals.
Become a customer from FAMAGA, get industrial machinery with no delays and at profitable price. Fill in information in the order form on the website. Our employee will contact you to discuss details. Inquiries are also accepted by phone.
General specifications | ||
---|---|---|
Switching function | Normally open (NO) | |
Output type | PNP | |
Rated operating distance | 40 mm | |
Installation | non-flush | |
Output polarity | DC | |
Assured operating distance | 0 ... 32.4 mm | |
Actual operating distance | 36 ... 44 mm typ. 40 mm | |
Reduction factor rAl | 0.33 | |
Reduction factor rCu | 0.31 | |
Reduction factor r304 | 0.74 | |
Reduction factor rBrass | 0.38 | |
Output type | 3-wire | |
Nominal ratings | ||
Operating voltage | 10 ... 30 V DC | |
Switching frequency | 0 ... 180 Hz | |
Hysteresis | typ. 5 % | |
Reverse polarity protection | reverse polarity protected | |
Short-circuit protection | pulsing | |
Voltage drop | &le, 2 V | |
Operating current | 0 ... 200 mA | |
Off-state current | 0 ... 0.5 mA | |
No-load supply current | &le, 20 mA | |
Time delay before availability | 80 ms | |
Operating voltage indicator | LED, green | |
Switching state indicator | LED, yellow | |
Functional safety related parameters | ||
MTTFd | 1057 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Compliance with standards and directives | ||
Standard conformity | ||
Standards | EN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 | |
Approvals and certificates | ||
Protection class | II | |
Rated insulation voltage | 253 V | |
Rated impulse withstand voltage | 4000 V | |
UL approval | cULus Listed, General Purpose | |
CCC approval | CCC approval / marking not required for products rated &le,36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 85 °C (-13 ... 185 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Mechanical specifications | ||
Connection type | Connector plug M12 x 1 , 4-pin | |
Housing material | PA | |
Sensing face | PA | |
Degree of protection | IP69K | |
Cable | ||
Cable diameter | 3.3 mm ± 0.15 mm | |
Mass | 130 g | |
Data for application in connection with hazardous areas | ||
Equipment protection level | Gc (nA) , Dc | |
Equipment protection level Gc (nA) | ||
Type of protection | n | |
CE marking | [*PD-Z02586A*] | |
Certificates | ||
ATEX certificate | PF15CERT3754X | |
ATEX marking | II 3G Ex nA IIC T6 Gc | |
Standards | EN 60079-0:2012+A11:2013 , EN 60079-15:2010 | |
Possible characteristics | maximum operating voltage UBmax , maximum load current ILmax , minimum series resistance RV , maximum analog output voltage UAmax , maximum analog output current IAmax | |
Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at UBmax = 30 V , IL = 200 mA : 48 °C (118.4 °F) at UBmax = 30 V , IL = 100 mA : 50 °C (122 °F) at UBmax = 30 V , IL = 50 mA : 51 °C (123.8 °F) at UBmax = 30 V , IL = 25 mA : 52 °C (125.6 °F) | |
Equipment protection level Dc | ||
Type of protection | Protection by enclosure tc | |
CE marking | [*PD-Z02586A*] | |
Certificates | ||
ATEX certificate | PF15CERT3774X | |
ATEX marking | II 3D Ex tc IIIC T80°C Dc | |
Standards | EN 60079-0:2012+A11:2013 , EN 60079-31:2014 | |
Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at UBmax = 30 V , IL = 200 mA : 48 °C (118.4 °F) at UBmax = 30 V , IL = 100 mA : 50 °C (122 °F) at UBmax = 30 V , IL = 50 mA : 51 °C (123.8 °F) at UBmax = 30 V , IL = 25 mA : 52 °C (125.6 °F) | |
General information | ||
Use in the hazardous area | see instruction manuals |