We are not the manufacturer, authorised distributor or authorised representative of the Keyence brand in Australia. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Keyence
Country
Japan
Name
LV-N11CN
Type
Mounting bracket
Description
Amplifier, M8 Connector, Main unit, NPN
Stock availability:
On request
If you require LV-N11CN from manufacturer Keyence, please contact FAMAGA.
For more than 8 years our specialists supply repair parts for the upgrading and maintenance of various types of manufacturing equipment from all corners of the earth. Over 700 orders from clients from different countries are in progress daily. Developed partner network provides an opportunity to execute without delay order for Keyence LV-N11CN, while the buyer does not have to go over budget.
Geography of deliveries includes Europe, America, Africa and Asia. Australia, India, Indonesia, United States, Mauritius, Malaysia, Dominican Republic, Yemen, Mozambique, Djibouti, San Marino, Latvia, Seychelles, Poland, Guinea, Oman, Mauritania, Senegal, Tanzania, Belize, Albania, Honduras, Colombia, Iraq, Nepal, Ethiopia, South Korea, Guatemala, Samoa, Morocco, Cape Verde, Gambia, Serbia, Guyana, Slovakia, Myanmar, Japan, Kyrgyzstan, Armenia, Lesotho, Syria, Central African Republic, Singapore, Benin, Antigua and Barbuda, Kiribati, Netherlands, France, Ghana, Burundi, Guinea-Bissau, Papua New Guinea, Côte d\'Ivoire, Eswatini There is no restrictions on the size and weight of the cargo. We developed different delivery options so that a client can choose optimal compromise between cost and delivery time.
Company`s fundamental rule of operation is transparency, which involves every sphere of activity. Customers get only high-quality products, to which relevant documentation from the manufacturer is available. All spare parts and equipment are original, likelihood of counterfeits are excluded. For permanent buyers there are very good terms and they are valid special pricing.
Become a customer from FAMAGA, get industrial machinery with no delay and at beneficial price. Fill in information in the order form on the website. Manager will contact you to discuss nuances. Requests are also accepted by phone.
Model | LV-N11CN | |
Type | 1 output | |
Output | NPN | |
Cable/connector | M8 connector | |
Main/Expansion unit | Main unit | |
I/O | Control outputs | 1 output |
External input | 1 input | |
Monitor output | None | |
Response time | 80 µs (HIGH SPEED)/250 µs (FINE)/500 µs (TURBO)/1 ms (SUPER)/4 ms (ULTRA)/16 ms (MEGA) *1 | |
Output selection | LIGHT-ON/DARK-ON (switch-selectable) | |
Timer function | Timer OFF/OFF-delay timer/ON-delay timer/One-shot timer, Timer duration selectable: 1 ms to 9,999 ms, Maximum error against the setting value: ±10% max. | |
Control outputs | NPN open collector 30 V, Residual voltage 1 V or less (Output current: 10 mA or less) / 2 V or less (Output current: 10 to 100 mA) (Stand-alone) 1 output max: 100 mA or less, 2 output total: 100 mA or less (Multiple connections) 1 output max: 20 mA or less | |
Monitor output | - | |
External input | Input time 2 ms (ON)/20 ms (OFF) or more*2 | |
Multiple connections to expansion units | Up to 17 units can be connected in total (two-output type is treated as two units) | |
Protection circuit | Reverse polarity protection, Over-current protection, Surge absorber | |
Number of interference prevention units | Connected to other than LV-S31: 0 for HIGH SPEED, 2 for FINE/TURBO/SUPER, 4 for ULTRA/MEGA, Connected to LV-S31: 2 for FINE, 4 for TURBO/SUPER/ULTRA/MEGA*3 | |
Case size | H 32.6 mm ? W 9.8 mm ? L 78.7 mm | |
Rating | Power voltage | 24 VDC (operating voltage 10 to 30 VDC (with ripple)), Ripple (P-P) 10 % or less, Class 2 or LPS |
Power consumption | Normal: 830 mW or less (at 30 V. 30 mA at 24 V, 56 mA or less at 12 V)*4 Eco on mode: 710 mW or less (at 30 V. 26 mA at 24 V, 48 mA or less at 12 V)*4 Eco Full mode: 550 mW or less (at 30 V. 21 mA at 24 V, 40 mA or less at 12 V) *5 | |
Environmental resistance | Ambient temperature | -20 to +55 °C (No freezing)*6 |
Relative humidity | 35 to 85 % RH (No condensation) | |
Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions | |
Shock resistance | 500 m/s2, 3 times in each of the X, Y, and Z directions | |
Material | Cable | PVC |
Case | Main unit and cover material: Polycarbonate | |
Weight | Approx. 20 g | |
*1 80 µs cannot be selected when the LV-S31/S62/S63 is connected *2 Input time is 25 ms (ON)/25 ms (OFF) when external calibration time is selected. *3 These numbers double when 'DOUBLE' is selected. *4 Increases 30 mW (1 mA) for High Speed mode. *5 It increases by 15% when connected to the LV-NH100/NH110/NH300. It does not include the power consumption of the load. Power consumption when expansion units are connected is the total power consumption of each amplifier unit. Example: When one main unit (LV-N11N) is connected to 2 expansion units (LV-N12N) and they are used with LV-NH100 heads in HIGH SPEED mode. (1.15 ? 860 mW ? 1) + (1.15 ? 860 mW ? 2) = 2967 mW max. *6 If more than one unit is used together, the ambient temperature varies with the conditions below. Mount the units on the DIN rail with mounting brackets and check that the output current is 20 mA or less for a unit. One or two more units connected: -20 °C to +55 °C , 3 to 10 more units connected: -20 °C to +50 °C, 11 to 16 more units connected: -20 °C to +45 °C. When using 2-outputs, one unit is counted as two units. |