We are not the manufacturer, authorised distributor or authorised representative of the Keyence brand in Australia. The private labels and part numbers shown on this website are the property of their respective owners.
If you require LR-TB5000C from manufacturer Keyence, please contact FAMAGA.
For more than 8 years our employees supply spare parts for the upgrading and maintenance of various types of technical equipment from all corners of the earth. Over 700 orders from clients from countries of near and far abroad are in progress daily. Developed partner network allows you to quickly execute order for Keyence LR-TB5000C, while the customer does not have to worry about extra costs.
Geography of deliveries involves Europe, Africa, America and Asia. Australia, India, Indonesia, United States, Ukraine, Venezuela, Malta, The Gambia, Turkmenistan, Guinea-Bissau, Burkina Faso, Czech Republic, San Marino, Panama, Samoa, South Korea, Djibouti, Estonia, Bosnia and Herzegovina, Brazil, Namibia, Argentina, Switzerland, Ireland, Tanzania, Eswatini, Zimbabwe, Gabon, Antigua and Barbuda, Central African Republic, Oman, Mongolia, China, Bahrain, Lithuania, Netherlands, Nepal, Cambodia, Iraq, Syria, Gambia, Egypt, Poland, Kyrgyzstan, Bahamas, Chile, Lesotho, Senegal, Bhutan, Honduras, Liberia, Mauritania, Guyana, Lebanon, South Sudan, Nicaragua, Vietnam, Luxembourg, Mali, Côte d\'Ivoire, Ethiopia, Sri Lanka There is no restrictions on the size and weight of the cargo. We offer different delivery options so that a buyer can choose optimal compromise between cost and delivery time.
Company`s fundamental rule of operation is transparency, which covers every sphere of activity. Customers get only high-quality products, to which factory warranty applies. All spare parts and equipment are original, risk of presence of counterfeits are excluded. For permanent customers there are exclusive offers and they are valid special pricing.
Become a buyer from FAMAGA, get components with no delays and at attractive price. Fill in the order form on the website. Our employee will contact you to specify details. Requests are also accepted by phone.
Model | LR-TB5000C | |
Type | Cable with connector M12 | |
Detectable distance | 60 to 5000 mm*1 | |
Spot diameter | Variable (use a spot diameter of 40 mm or less) | |
Response time | 1 ms/10 ms/25 ms/100 ms/1000 ms selectable | |
Light source | Type | Red laser (660 nm) |
Laser class | Class 2 laser product (IEC60825-1,FDA (CDRH) Part1040.10*2) | |
Mutual interference prevention function | 4 units (when using the interference prevention function) | |
Timer | OFF/OFF delay/ON delay/One-shot | |
Power voltage | 20 to 30 VDC, including 10% ripple (P-P), Class 2 or LPS | |
Current consumption | 50 mA or less (without load)*3 | |
I/O | Control output | NPN open collector/PNP open collector selectable 30 VDC or less, 50 mA or less, residual voltage: 2 V or less, N.O./N.C. selectable *4*5 |
External input | Switchable between transmission OFF, teaching, and reference surface update Short-circuit current: 1 mA or less for both NPN and PNP For the applied voltage, see the wiring diagrams (pages 2 and 3 in the instruction manual). For the input times, see the time charts (page 4 in the instruction manual).*3 | |
Analogue output | Current output/Voltage output selectable Current output: 4 to 20 mA with a max. load resistance of 500 ? Voltage output: 0 to 10 V with an external load resistance of 5 k? or more *4*5 | |
Protection circuit | Protection against reverse power connection, power supply surges, output overcurrent, reverse output connection, and output surge | |
Environmental resistance | Enclosure rating | IP65/IP67 (IEC60529) |
Ambient light | Incandescent lamp/Sunlight: 10,0000 lux or less | |
Ambient temperature | -20 to +55 °C (No freezing) | |
Relative humidity | 35 to 85 % RH (No condensation) | |
Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions | |
Shock resistance | 1,000 m/s2, 6 times in each of the X, Y, and Z directions | |
Material | Case: Zinc die cast (Nickel chrome plating), Indicator cover and buttons: PES, Lens cover and display: PMMA (scratch-resistant coating specifications), Cable bushing: PBT, Cable: PVC, M12 connector: TPE, PBT, Nickel-plated brass | |
Accompanying items | Instruction manual, Laser warning and explanation labels | |
Weight | Approx. 160 g | |
*1 The range for displayable distance is from 50 to 5200. *2 The laser classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice No.50. *3 150 mA or less (with load) *4 You can select the I/O from the following combinations. Control output ? 2, control output + external input Control output + analogue output (LR-TB5000/TB5000C/TB5000CL only), External input + analogue output (LR-TB5000/TB5000C/TB5000CL only) (For details on the setting method, see the instruction manual.) *5 IO-Link specification v.1.1/COM2 (38.4 kbps) is supported. You can download a setup file from the KEYENCE website (http://www.keyence.com). If you are using the product in an environment in which you cannot download files over the Internet, contact your nearest KEYENCE office. |