We are not the manufacturer, authorised distributor or authorised representative of the Keyence brand in Australia. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Keyence
Country
Japan
Name
IL-1050
Type
Mounting bracket
Description
MULTIFUNKTIONS-CMOS-LASERSENSOR FÜR DIN-SCHIENENMONTAGE-UNTEREINHEIT
Stock availability:
On request
If you require IL-1050 from manufacturer Keyence, please contact FAMAGA.
For more than 9 years our managers supply repair parts for the repairs and maintenance of various types of manufacturing equipment from all over the world. Over 750 orders from clients from various countries are in service daily. Developed partner network allows you to quickly execute order for Keyence IL-1050, while the buyer does not have to go over budget.
Geography of deliveries involves Europe, America, Asia and Africa. Australia, India, Indonesia, United States, Dominican Republic, Sudan, Grenada, San Marino, Azerbaijan, South Korea, Russia, Jordan, Namibia, Uruguay, Argentina, Algeria, Vietnam, Costa Rica, Angola, Albania, Cape Verde, Gambia, Senegal, Jamaica, Burkina Faso, United Arab Emirates, Nicaragua, Myanmar, Mongolia, Moldova, Paraguay, Yemen, Philippines, Bosnia and Herzegovina, Palestine, Slovenia, Zambia, Italy, Bangladesh, Uzbekistan, Montenegro, Netherlands, Poland, Benin, Bahamas, Denmark, Central African Republic, Chile, Armenia, Serbia, Honduras, Canada, Japan, Ethiopia, Lebanon, France, Liberia, Mali, Botswana, Guinea-Bissau, Malawi There is no restrictions on the size and mass of the cargo. We offer different delivery options so that a buyer can choose suitable balance between cost and delivery time.
Company`s main postulate is transparency, which covers every segment of activity. Clients get top-class spare parts and equipment, to which factory warranty applies. All repair parts and equipment are original, risk of presence of counterfeits are excluded. For permanent customers there are loyalty programs and they are valid great deals.
Become a customer from FAMAGA, get machine-tools fast and at profitable price. Fill in the order form on the website. Our specialist will contact you to specify details. Inquiries are also accepted by phone.
Model | IL-1050 | |
Type | DIN-rail mount | |
Main unit/Expansion unit | Expansion unit | |
Head compatibility | Compatible | |
Display | Minimum displayable unit | IL-S025/IL-030: 1 µm, IL-S065/IL-065/IL-100: 2 µm, IL-300: 10 µm, IL-600: 50 µm |
Display range | IL-S025/IL-030/IL-S065/IL-065/IL-100: ±99.999 mm to ±99 mm (4 levels selectable), IL-300/IL-600: ±999.99 mm to ±999 mm (3 levels selectable) | |
Display rate | Approx. 10 times/sec. | |
Analogue voltage output | None | |
Analogue current output | ||
Control input | Bank switch input | Non-voltage input*1 |
Zero-shift input | ||
Stop emission input | ||
Timing input | ||
Reset input | ||
Control output | Judgment output | Open collector output (NPN, PNP changeover possible/N.O., N.C. changeover possible)*2 |
Alarm output | Open collector output (NPN, PNP changeover possible/N.C.)*2 | |
Current | Power voltage | Supplied by main unit*3 |
Power consumption | 2000 mW or less (at 30 V: 67 mA or less) | |
Environmental resistance | Pollution degree | 2 |
Ambient temperature | -10 to +50 °C (No condensation or freezing) | |
Relative humidity | 35 to 85 % RH (No condensation) | |
Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions | |
Material | Case / Front sheet: Polycarbonate, Key tops: Polyacetel, Cable: PVC | |
Weight | Approx. 140 g (including attachments) | |
*1 Assign an input of your choice to the 4 external input lines before using. *2 The NPN open collector rated output is: 50 mA max./ch (20 mA when adding an expansion unit) less than 30 V, residual voltage less than 1 V (less than 1.5 V when adding over 6 units including the main unit) The PNP open collector rated output is: 50 mA max./ch (20 mA/ch when adding expansion units), less than power voltage, and less than 2 V residual voltage (less than 2.5 V when adding over 6 units including the main unit) *3 If there are over 6 additional expansion units, please use a power voltage of 20 to 30 V. |