We are not the manufacturer, authorised distributor or authorised representative of the Keyence brand in Australia. The private labels and part numbers shown on this website are the property of their respective owners.
If you require GL-R63F from manufacturer Keyence, please contact FAMAGA.
For more than 9 years our employees supply spare parts for the upgrading and maintenance of various types of manufacturing equipment from all corners of the earth. Over 700 orders from clients from countries of near and far abroad are in service daily. Developed partner network provides an opportunity to execute without delay order for Keyence GL-R63F, while the client does not have to spend more than planned amount.
Geography of deliveries involves Europe, America, Africa and Asia. Australia, India, Indonesia, United States, Tajikistan, Nigeria, Kazakhstan, Germany, Congo, Ukraine, United Kingdom, The Gambia, Central African Republic, Swaziland, Mauritius, Uzbekistan, Lithuania, Djibouti, Laos, Burkina Faso, Singapore, Ethiopia, Denmark, Oman, Honduras, Montenegro, Peru, Portugal, Bosnia and Herzegovina, Vietnam, South Africa, Armenia, South Korea, Uruguay, Dominica, Liechtenstein, Zambia, Seychelles, Ecuador, Malawi, Bangladesh, Fiji, Kiribati, Bahamas, Luxembourg, Jamaica, Benin, Haiti, Poland, Bhutan, Lebanon, Yemen, Equatorial Guinea, Canada, Mozambique, Croatia, Niger, Barbados, Switzerland, Japan, Suriname, Cape Verde There is no restrictions on the size and weight of the cargo. We developed different delivery options so that a client can choose optimal compromise between cost and delivery time.
Company`s fundamental rule of operation is transparency, which involves every segment of activity. Customers get top-class spare parts and equipment, to which relevant documentation from the manufacturer is available. All spare parts and equipment are original, likelihood of counterfeits are excluded. For permanent partners there are loyalty programs and they are valid great deals.
Become a partner from FAMAGA, get components with no delays and at beneficial price. Fill in information in the order form on the website. Our employee will contact you to discuss nuances. Inquiries are also accepted by phone.
Model | GL-R63F | ||
Detection capability | o14 mm | ||
Beam axis spacing/Lens diameter | 10 mm / o4 | ||
Detecting distance | 0.2 to 10 m*1 | ||
Effective aperture angle | Max. ±2.5° (When operating distance is 3 m or more) | ||
Light source | Infrared LED (870 nm) | ||
Response time (OSSD) (ms) | Wire synchronisation, One-line or Optical synchronisation system (Channel 0) | ON>OFF | 11.2 |
OFF>ON | 55.6*2 | ||
All blocked>ON | 81.7*3 | ||
Optical synchronisation system (Channel A or B) | ON>OFF | 16.3 | |
OFF>ON | 63.2*2 | ||
All blocked>ON | 101.8*3 | ||
Detection mode | Turns on when no interruptions are present in the detection zone | ||
Synchronisation between the transmitter and receiver | Optical synchronisation or Wire synchronisation (Determined by wiring) | ||
Light interference prevention function | Prevents mutual interference in up to two GL-R systems. Optical synchronization: prevented by Channel A and B with setting switch Wire synchronization: prevented automatically | ||
Control output (OSSD output) | Output | 2 transistor outputs. (PNP or NPN is determined by the cable type) | |
Max. load current | 500 mA*4 | ||
Residual voltage (during ON) | Max. 2.5 V (with a cable length of 5 m) | ||
OFF state voltage | Max. 2.0 V (with a cable length of 5 m) | ||
Leakage current | Max. 200 µA | ||
Max. capacitive load | 2.2 µF | ||
Load wiring resistance | Max. 2.5 ? | ||
Supplemental output (Non-safety-related output) | AUX | transistor outputs. (PNP or NPN is determined by the cable type) Load current: Max. 50 mA, Residual voltage: Max. 2.5 V (with a cable length of 5 m) | |
Error output | |||
Muting lamp output | Incandescent lamp (24 VDC, 1 to 5.5 W) LED lamp (load current: 10 to 230 mA) can be connected. | ||
External input | When using a PNP output cable | EDM input Wait input Reset input Muting input 1, 2 Override input | ON voltage: 10 to 30 V OFF voltage: Open or 0 to 3 V Short circuit current: Approx. 2.5 mA (Approx. 10 mA with EDM input only) |
When using an NPN output cable | ON voltage: 0 to 3 V OFF voltage: Open or 10 V or more Up to the power voltage Short circuit current: Approx. 2.5 mA (Approx. 10 mA with EDM input only) | ||
Rating | Power voltage | 24 VDC ±20%, ripple (P-P) 10% or less, Class 2 | |
Power supply | Current consumption (Max.) (mA) | Transmitter | 64 |
Receiver | 77 | ||
Protection circuit | Reverse current protection, short-circuit protection for each output, surge protection for each output | ||
Approved standards | EMC | EMS | IEC61496-1, EN61496-1, UL61496-1 |
EMI | EN55011 ClassA, FCC Part15B ClassA, ICES-003 ClassA | ||
Safety | IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE) IEC61496-2, EN61496-2, UL61496-2 (Type 4 AOPD) IEC61508, EN61508 (SIL3), IEC62061, EN62061 (SIL CL3) EN ISO13849-1:2015 (Category 4, PLe) UL508 UL1998 | ||
Environmental resistance | Enclosure rating | IP65/IP67 (IEC60529) | |
Overvoltage category | II | ||
Ambient light | Incandescent lamp: 3,000 lux or less, Sunlight: 20,000 lux or less | ||
Operating ambient temperature | -10 to +55 °C (No freezing) | ||
Storage temperature | -25 to +60 °C (No freezing) | ||
Operating relative humidity | 15 to 85 % RH (No condensation) | ||
Storage relative humidity | 15 to 95 % RH | ||
Vibration resistance | 10 to 55 Hz, Double amplitude 0.7 mm, 20 sweeps in each of the X, Y, and Z directions | ||
Shock resistance | 100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions | ||
Material | Main unit case | Aluminium | |
Upper case/lower case | Nylon (GF 30%) | ||
Front cover | Polycarbonate, SUS304 | ||
Weight | Transmitter | 890 g | |
Receiver | 900 g | ||
*1 When the option front protection cover is installed on the one of transmitter or receiver, the Operating distance is shorten by 0.5 m. When the front covers are installed on both of the transmitter and receiver, the Operating distance is shorten by 1.0 m. *2 If the interruption is present in the detection zone for less than 80 ms, the response time (OFF to ON) will be 80 ms or more to ensure that the OSSD maintains the OFF state for more than 80 ms. *3 “All blocked” means the situation where the GL-R operates in optical synchronisation system and the transmitter and receiver is not synchronised (top and bottom beam axes are both blocked). In this situation, the response time is longer because the GL-R synchronises the transmitter and receiver fi rst and then determines the clear or blocked. *4 When the GL-R is used under surrounding air temperatures between 50 to 55°C, the Maximum load current should not exceed 350 mA. |